Indicators, Codes, and Messages 25
Memory parity failure at
start address
to
end
address
Faulty or improperly installed memory
modules.
See "Troubleshooting System Memory"
in "Troubleshooting Your System."
Memory parity error at
address
No boot device available Faulty or missing CD/diskette drive
subsystem, hard drive, or hard-drive
subsystem.
Use a bootable diskette, CD, or hard
drive. If the problem persists, see
"Troubleshooting a Diskette Drive,"
"Troubleshooting a CD Drive,"
"Troubleshooting SCSI Hard Drives,"
and "Troubleshooting SATA Hard
Drives" in "Troubleshooting Your
System."
No boot sector on hard-
disk
No operating system on hard drive. Check the hard-drive configuration
settings in the System Setup program.
See "Using the System Setup Program"
in the User's Guide.
No PXE-capable device
available
<F12> pressed during POST and no
PXE devices are detected.
Check the configuration settings in the
System Setup program for the NICs. See
"Using the System Setup Program" in
the User's Guide. If the problem persists,
see "Troubleshooting a NIC" in
"Troubleshooting Your System."
No timer tick interrupt Faulty system board. See "Getting Help."
Not a boot diskette No operating system on diskette. Use a bootable diskette.
PCI BIOS failed to install Loose cables to expansion card(s);
faulty or improperly installed
expansion card.
Ensure that all appropriate cables are
securely connected to the expansion
cards. If the problem persists, see
"Troubleshooting Expansion Cards" in
"Troubleshooting Your System."
Table 2-8. System Messages (continued)