TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR86
Message Bad block table on
arg1
is full.
Arguments
arg1 =
physical disk
Detailed
Description
The number of blocks on the disk that exhibit an error has exceeded the capacity of the drive to
remap. Any future writes to bad sectors will be unrecoverable.
Recommended
Response Action
Replace the disk.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR87
Message
arg1
was reset.
Arguments
arg1 =
physical device
Detailed
Description
The physical device was reset. This is a normal part of operations and is not a cause for
concern.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.