72 Installing System Options
Figure 3-10. Removing and Installing an I/O Module
Installing an I/O Module
1
Unpack the I/O module and prepare it for installation.
For instructions, see the documentation that accompanied the module.
2
Install the I/O module.
NOTE: Bays IO/1 and IO/2 accept only PowerConnect 5316M Ethernet switch modules or Gb Ethernet pass-
through modules. If only one module is used, it must be installed in bay IO/1. Bay IO/2 is for a second
PowerConnect 5316M Ethernet switch module or Gb Ethernet pass-through module for redundancy.
a
Ensure that the I/O module release lever is fully extended. See Figure 3-10.
b
Slide the module into the chassis until it is fully seated.
c
Close the release lever until it snaps securely into place.
3
If a daughter card(s) was included with the new I/O module, install the daughter card(s). See
"I/O
Module Daughter Card" on page 82
.
NOTE: The daughter card enables a server module to communicate with the corresponding connector
number on its appropriate I/O module. For example, server module number 5 must have a Fibre-Channel
daughter card installed to communicate with the Fibre Channel pass-through module connector number 5
(primary and secondary bays).
1 I/O module 2 release lever
2
1