Dell Precision Workstation 620 Computer
NOTE: Precision Workstation 620 computers do not have an event log.
Fan Failure Boot Message (F1/F2)
AGP card-cage fan During
boot
No message
Run time No message
CPU fan During
boot
Alert! CPU fan not detected
Run time On next boot: Alert! Previous system fan failure
CPU 0 During NOTE: The computer will shut down if this issue is not resolved within about 1
Overtemp boot minute.
On next boot: Alert! Previous shutdown due to thermal event
CPU 1 During NOTE: The computer will shut down if this issue is not resolved within about 1
Overtemp boot minute
On next boot: Alert! Previous temperature failure at Processor 1
System During System immediately shuts down!
Thermtrip boot
On next boot: Alert! Previous shutdown due to thermal event
Run time System immediately shuts down!
On next boot: Alert! Previous shutdown due to thermal event
Power supply fan 1 During
boot
Alert! Power supply fan failure
Run time On next boot: Alert! previous power supply fan failure
Power supply fan 2 During
boot
Alert! Power supply fan failure
Run time On next boot: Alert! Previous power supply fan failure
System fan (memory riser During Alert! System fan not detected
fan) boot
Run time On next boot: Alert! Previous system fan failure
PN D0744 — CPU/system fan (service kit to replace fan, not the bracket, which can
be reused.)
Seitenansicht 9