Seitenansicht 108
Chassis Information Group 111
Table 5-6. Front-Panel LED Control Settings
Variable Name:
DellLEDControlSettings
Data Type: Integer
Possible Data Values Meaning of Data Value
unknown(1) The LED control setting is unknown.
alertOnError(2) The LED control is set to alert on an error
condition.
alertOnWarningAndError(4) The LED control is set to alert on an error or
a warning condition.
Table 5-7. Hard-Drive Fault LED Control Capabilities
Variable Name: DellHDFaultLEDControlCapabilities
Data Type: Integer
Possible Data Values Meaning of Data Value
none(0) The hard drive has no fault LED
capabilities.
unknownCapabilities(1) The hard-drive fault LED capabilities are
unknown.
enableCapable(2) The hard-drive fault LED can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4) The hard-drive fault LED can indicate not
ready.
resetCapable(8) The hard-drive fault LED can be reset.
book.book Page 111 Wednesday, March 6, 2013 12:37 AM