Dell OpenManageSNMP Reference Guide Version 7.4
See Physical Memory Array Table for more information.– Added the following new varbind for:Baseboard Management Controller Group * Added new MIB varbi
Description Defines the share disposition of the system resource DMA.Syntax DellResourceShareDisposition (Resource Share Disposition)Access Read-on
Table 326. Resource Owner Interface TypeVariable Name: DellResourceOwnerInterfaceType Data Type: Integer Possible Data Values Meaning of Data Value ty
memoryIsF24(16)The resource memory is F24.Table 329. Resource Interrupt TypeVariable Name: DellResourceInterruptType Data Type: Integer Possible Data
dmaTransferWidthIs16Bits(4) The DMA transfer width is 16 bits.dmaTransferWidthIs32Bits(5) The DMA transfer width is 32 bits.dmaTransferWidthIs64Bits(6
Access Read-onlyIndex powerUnitchassisIndex, powerUnitIndexTable 335. Power Unit Chassis IndexName powerUnitchassisIndexObject ID 1.3.6.1.4.1.674.1
Table 340. Power Supply Count for RedundancyName powerSupplyCountForRedundancyObject ID 1.3.6.1.4.1.674.10892.1.600.10.1.6Description Defines the to
Table 345. Power Supply Chassis IndexName powerSupplychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.1Description Defines the index (one-base
Table 350. Power Supply Output WattsName powerSupplyOutputWattsObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.6Description Defines the maximum sustained
Description Defines the state reported by the power supply sensor, and supplements the state and settings of the power supply.Syntax DellPowerSupply
Description Defines the Voltage Probe Table entry.Syntax VoltageProbeTableEntryAccess Not accessibleIndex voltageProbechassisIndex, voltageProbeIn
MIB Name Agent / Hardware Supported Purpose of the MIBinstrumentation software. This is the primary MIB for PowerEdge systems.dcs3fru.mib Server Admin
Access Read-onlyTable 366. Voltage Probe ReadingName voltageProbeReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.6Description Defines the value o
Access Read-onlyTable 371. Voltage Probe Upper Noncritical ThresholdName voltageProbeUpperNonCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.600.2
Table 376. Voltage Probe Discrete ReadingName voltageProbeDiscreteReadingObject ID 1.3.6.1.4.1.674.10892.1.600.20.1.16Description Defines the readin
Description Defines the index of amperage probes in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 381. Amperage Probe State Capabilities
amperageProbeTypeIsSystemWatts, the value returned for this attribute is the amperage that the probe is reading in Milliamps.When the value for ampera
Description Defines the user-assigned value of the amperage probe’s upper critical threshold.Syntax DellSigned32BitRangeAccess Read-onlyTable 390.
When the value for amperageProbeType is other than amperageProbeTypeIsDiscrete, a value is not returned for this attribute. When the value for amperag
Table 399. AC Power Switch CapabilitiesName aCPowerSwitchCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.600.40.1.3Description Defines the capabilitie
Description Defines the redundancy mode of this AC power switch.Syntax DellACPowerSwitchRedundancyModeAccess Read-onlyTable 405. AC Power Switch St
Table 409. AC Power Cord IndexName aCPowerCordIndexObject ID 1.3.6.1.4.1.674.10892.1.600.42.1.2Description Defines the index (one-based) of this AC
group number>, where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant section for more information abou
Description Defines the location name of this AC power cord.Syntax DellStringAccess Read-onlyBattery TableTable 415. Battery TableName batteryTable
Access Read-onlyTable 420. Battery State SettingsName batteryStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.600.50.1.4Description Defines the state
Table 425. Power Usage Table EntryName powerUsageTableEntryObject ID 1.3.6.1.4.1.674.10892.1.600.60.1Description Defines the Power Usage Table Entry
Table 430. Power Usage StatusName powerUsageStatusObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.5Description Defines the status of the power usage info
Table 435. Power Usage Peak Watts Start Date NameName powerUsagePeakWattsStartDateNameObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.10Description Defin
Table 440. Power Usage Idle PowerName powerUsageIdlePowerObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.15Description Defines the system idle power (in
Table 445. Power Usage Instantaneous HeadroomName powerUsageInstantaneousHeadroomObject ID 1.3.6.1.4.1.674.10892.1.600.60.1.20Description Defines th
Table 450. Power Profile IndexName powerProfileIndexObject ID 1.3.6.1.4.1.674.10892.1.600.70.1.2Description Defines the index (one-based) of the pow
Table 455. Power Profile Custom Memory Management CapabilitiesName powerProfileCustomMemoryManagementCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.60
onlineCapable(2) The power supply can be disabled (offline, a binary 0 value) or enabled (online, a binary 1 value).notReadyCapable(4) The power suppl
Section Topics MIB Group Numbers18 Cost of Ownership Group — defines variables for tracking data on the system’s service contract, lease, repair reco
powerSupplyTypeIsSwitching(4) The power supply type is a switching power supply.powerSupplyTypeIsBattery(5)The power supply type is a battery.powerSup
processorMissing(3)The power supply configuration error type is processor missing.Table 464. Voltage Probe TypeVariable Name: DellVoltageType Data Typ
Table 466. Amperage Probe DefinitionsVariable Name: DellAmperageType Data Type: IntegerPossible Data Values Meaning of Data Value amperageProbeTypeIs
amperageProbeTypeIsSystemWatts(26) The amperage probe type is system probe with reading in Watts.Table 467. Amperage Probe Discrete ReadingVariable Na
nonRedundant(1) The AC power switch is not expecting redundancy.redundant(2)The AC power switch is expecting redundancy.Table 471. AC Power Cord State
NOTE: These values are bit masks, so combination values are possible.Possible Data Values Meaning of Data Value none(0) No power cap capabilities are
systemDBPM(8) CPU power and performance management type is System Demand Based Power Management.Table 478. Memory Power Performance Management TypeVar
• Temperature Probe TableCooling Unit TableTable 480. Cooling Unit TableName coolingUnitTableObject ID 1.3.6.1.4.1.674.10892.1.700.10Description Def
Access Read-onlyTable 485. Cooling Unit State SettingsName coolingUnitStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.10.1.4Description Defines
Cooling Device TableTable 490. Cooling Device TableName coolingDeviceTableObject ID 1.3.6.1.4.1.674.10892.1.700.12Description Defines the Cooling De
1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant se
Access Read-onlyTable 495. Cooling Device State SettingsName coolingDeviceStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.4Description Defi
Access Read-onlyTable 500. Cooling Device Upper Nonrecoverable ThresholdName coolingDeviceUppernonrecoverableThresholdObject ID 1.3.6.1.4.1.674.1089
Table 505. Cooling Device Lower Nonrecoverable ThresholdName coolingDeviceLowerNonRecoverableThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.12.1.14De
Temperature Probe TableTable 510. Temperature Probe TableName temperatureProbeTableObject ID 1.3.6.1.4.1.674.10892.1.700.20Description Defines the T
Access Read-onlyTable 515. Temperature Probe State SettingsName temperatureProbeStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.4Description
Syntax DellStringAccess Read-onlyTable 520. Temperature Probe Upper Nonrecoverable ThresholdName temperatureProbeUpperNonRecoverableThresholdObject
Access Read-onlyTable 525. Temperature Probe Lower Nonrecoverable ThresholdName temperatureProbeLowerNonRecoverableThresholdObject ID 1.3.6.1.4.1.67
coolingDeviceTypeIsABlower(4)The cooling device type is a centrifugal blower.coolingDeviceTypeIsAChipFan(5)The cooling device type is a fan on an inte
Possible Data Values Meaning of Data Value temperatureProbeTypeIsOther(1)The temperature probe subtype is not one of the following:temperatureProbeTy
Access Not accessibleIndex remoteFlashBIOSchassisIndex, remoteFlashBIOSIndexTable 535. Remote Flash BIOS Chassis IndexName remoteFlashBIOSchassisInd
Table 5. Server Administrator Change Management MIB Sections in This GuideSection Topics MIB Group Number24 Change Management Group - describes the i
Table 539. Remote Flash BIOS StatusName remoteFlashBIOSStatusObject ID 1.3.6.1.4.1.674.10892.1.900.10.1.5Description Defines the status of the remot
unknown(1) The remote flash BIOS’s capabilities are unknown.enableCapable(2) The remote flash BIOS can be disabled (offline, a binary 0 value) or enab
completionCodeIsNoExternalPower(10) An external power adapter must be connected.completionCodeIsNo12VoltSet(11) 12 volts (V) could not be set.completi
Description Defines the Pointing Port Table entry.Syntax PointingPortTableEntryAccess Not accessibleIndexpointingPortchassisIndex,pointingPortIndexTab
Table 552. Pointing Port StatusNamepointingPortStatusObject ID 1.3.6.1.4.1.674.10892.1.1000.10.5Description Defines the status of the pointing port.Sy
Keyboard Port TableTable 557. Keyboard Port TableName keyboardPortTableObject ID 1.3.6.1.4.1.674.10892.1.1000.20Description Defines the Keyboard Port
Description Defines the capabilities of the keyboard port.Syntax DellStateCapabilitiesAccess Read-onlyTable 562. Keyboard Port State SettingsName keyb
Syntax DellStringAccess Read-onlyTable 567. Keyboard Port BIOS Connector TypeName keyboardPortBIOSConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.
Table 571. Processor Port IndexNameprocessorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.30.1.2Description Defines the index of the processor ports
Table 576. Processor Port Connector TypeNameprocessorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.30.1.7Description Defines the connector t
Basic TerminologyIt is important to have a good understanding of the key technical terms used in this guide. This guide provides definitions for all e
IndexmemoryDevicePortchassisIndex,memoryDevicePortIndexTable 581. Memory Device Port Chassis IndexNamememoryDevicePortchassisIndexObject ID 1.3.6.1.4.
Syntax DellStatusAccess Read-onlyTable 586. Memory Device Port Security StateNamememoryDevicePortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.4
Syntax DellUnsigned32BitRangeAccess Read-onlyTable 591. Memory Device Port Physical Memory Card Index ReferenceNamememoryDevicePortPhysicalMemoryCardI
Table 595. Monitor Port IndexName monitorPortIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.2Description Defines the index of the monitor ports in t
Table 600. Monitor Port Connector TypeName monitorPortConnectorTypeObject ID 1.3.6.1.4.1.674.10892.1.1000.50.1.7Description Defines the connector type
,sCSIPortIndexTable 605. SCSI Port Chassis IndexNamesCSIPortchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.1Description Defines the index (on
Access Read-onlyTable 610. SCSI Port Security StateNamesCSIPortSecurityStateObject ID 1.3.6.1.4.1.674.10892.1.1000.60.1.6Description Defines the secur
Access Not accessibleTable 615. Parallel Port Table EntryNameparallelPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1000.70.1Description Defines the
Description Defines the state and settings of the parallel port.Syntax DellStateSettingsAccess Read-onlyTable 620. Parallel Port StatusNameparallelPor
Syntax DellParallelPortConnectorPinoutAccess Read-onlyTable 625. Parallel Port Capabilities UniqueNameparallelPortCapabilitiesUniqueObject ID 1.3.6.1.
Table 8. UUID TableName uUIDTableObject ID 1.3.6.1.4.1.674.10892.1.300.20Description Defines the UUID table.Syntax SEQUENCE OF UUIDTableEntryAccess
Syntax IntegerSerialPortTableEntryAccess Not accessibleTable 630. Serial Port Table EntryNameserialPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.100
Table 634. Serial Port State SettingsNameserialPortStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.4Description Defines the state and setting
Table 639. Serial Port Maximum SpeedNameserialPortMaximumSpeedObject ID 1.3.6.1.4.1.674.10892.1.1000.80.1.9Description Defines the maximum speed the s
Access Not accessibleTable 644. USB Port Table EntryNameuSBPortTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1Description Defines the USB Port T
Access Read-onlyTable 649. USB Port StatusNameuSBPortStatusObject ID 1.3.6.1.4.1.674.10892.1.1000.90.1.5Description Defines the state of the USB port.
connectorPortTypeIsOther(1)The pointing port connector type is not one of the following:connectorPortTypeIsUnknown(2)The pointing port connector type
connectorPortTypeIsAccessBusUSB(9)The keyboard port connector type is bus USB.connectorPortTypeIsPC98(10)The keyboard port connector type is PC-98.Tab
connectorPortTypeIsZIP(7)The memory device port connector type is a ZIP.connectorPortTypeIsAProprietaryCard(8)The memory device port connector type is
about type, settings, configuration, manufacturer, address or location, and if applicable, the speed of the device.Device TablesThe following manageme
Table 661. Pointing Device Chassis IndexNamepointingDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.10.1.1Description Defines the index (one-
Access Read-onlyTable 13. UUID ValueName uUIDValueObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.4Description Defines the value of the UUID for this ch
Description Defines the index to the pointing port in this chassis.Syntax DellObjectRangeAccess Read-onlyTable 667. Pointing Device TypeNamepointingDe
Table 671. Keyboard Device Chassis IndexNamekeyboardDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.20.1.1Description Defines the index (one-
Description Defines the index to the associated the keyboard port in this chassis.Syntax DellStatusAccess Read-onlyTable 677. Keyboard Device Type Nam
Description Defines the index (one-based) of this chassis.Syntax DellObjectRangeAccess Read-onlyTable 682. Processor Device IndexNameprocessorDeviceIn
Table 687. Processor Device TypeNameprocessorDeviceTypeObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.7Description Defines the type of processor device.S
Description Defines the current speed of the processor device in MHz. A zero (0) indicates that the speed is unknown.Syntax DellUnsigned32BitRangeAcce
Description Defines the number of processor cores detected for the processor device.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 698. Processor
Table 701. Processor Device Extended CapabilitiesNameprocessorDeviceExtendedCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.21Description This
Table 704. Processor Device Model NameNameprocessorDeviceModelNameObject ID 1.3.6.1.4.1.674.10892.1.1100.30.1.24Description Defines the model of the p
Table 709. Processor Device Status IndexNameprocessorDeviceStatusIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.32.1.2Description Defines the index (one-
• The Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider, an extension of the standard management object f
Description Defines the location name of the processor device status probe.Syntax DellStringAccess Read-onlyTable 715. Processor Device Status Port In
Table 719. Cache Device IndexNamecacheDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.2Description Defines the index of the cache device in thi
Description Defines the type of cache device.Syntax DellCacheDeviceType (See Cache Device Type)Access Read-onlyTable 725. Cache Device LocationNamecac
Access Read-onlyTable 730. Cache Device Current SizeNamecacheDeviceCurrentSizeObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.13Description Defines the cu
Table 735. Cache Device AssociativityNamecacheDeviceAssociativityObject ID 1.3.6.1.4.1.674.10892.1.1100.40.1.18Description Defines the type of associa
,memoryDeviceIndexTable 740. Memory Device Chassis IndexNamememoryDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.1Description Defines t
Table 745. Memory Device Memory Port Index ReferenceNamememoryDeviceMemoryPortIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.6Description D
Access Read-onlyTable 750. Memory Device Type DetailsNamememoryDeviceTypeDetailsObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.11Description Defines the
Access Read-onlyTable 755. Memory Device Total Bus WidthNamememoryDeviceTotalBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.16Description Defines
Table 759. Memory Device Failure ModesNamememoryDeviceFailureModesObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.20Description Defines the failure modes
Notes, Cautions, and WarningsNOTE: A NOTE indicates important information that helps you make better use of your computer.CAUTION: A CAUTION indicates
Management Information Base Object IdentifiersEach data class within a Management Information Base (MIB) is defined by an Object Identifier (OID). OID
Table 764. Memory Device Speed NameNamememoryDeviceSpeedNameObject ID 1.3.6.1.4.1.674.10892.1.1100.50.1.25Description This attribute defines the speed
Access Not accessibleTable 768. Memory Device Mapped Address Table EntryNamememoryDeviceMappedAddressTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.
Syntax DellStateSettingsAccess Read-onlyTable 773. Memory Device Mapped Address StatusNamememoryDeviceMappedAddressStatusObject ID 1.3.6.1.4.1.674.108
Syntax DellUnsigned32BitRangeAccess Read-onlyTable 778. Memory Device Mapped Address Starting AddressNamememoryDeviceMappedAddressStartingAddressObjec
Table 782. Generic Device Chassis IndexNamegenericDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.70.1.1Description Defines the index (one-ba
Description Defines the index of the system slot into which this generic device is plugged.Syntax DellObjectRangeAccess Read-onlyTable 788. Generic De
Table 792. PCI Device Chassis IndexNamepCIDevicechassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.80.1.1Description Defines the index (one-based) of
Description Defines the index number of the system slot that this PCI device is in.Syntax DellObjectRangeAccess Read-onlyTable 798. PCI Device Data Bu
PCI Device Configuration Space TableTable 803. PCI Device Configuration Space TableNamepCIDeviceConfigurationSpaceTableObject ID 1.3.6.1.4.1.674.10892
Access Read-onlyTable 808. PCI Device Configuration Space State SettingsNamepCIDeviceConfigurationSpaceStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.
system and network management data is not confidential, this limited security is acceptable for Get types of requests. On the other hand, this securit
Table 813. PCI Device Configuration Space Function NumberNamepCIDeviceConfigurationSpaceFunctionNumberObject ID 1.3.6.1.4.1.674.10892.1.1100.82.1.9Des
Access Read-onlyTable 818. Network Device IndexNamenetworkDeviceIndexObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.2Description Defines the index (one-b
Table 823. Network Device Vendor NameNamenetworkDeviceVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.7Description Defines the name of the vendo
Description Defines the IP subnet mask for the IP address currently assigned to the network device.Syntax IpAddressAccess Read-onlyTable 829. Network
Syntax DellUnsigned8BitRangeAccess Read-onlyTable 834. Network Device PCI Device NumberNamenetworkDevicePCIDeviceNumberObject ID 1.3.6.1.4.1.674.10892
Table 839. Network Device TOE Capability FlagsNamenetworkDeviceTOECapabilityFlagsObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.23Description Defines the
Table 844. Network Device iSCSI EnabledNamenetworkDeviceiSCSIEnabledObject ID 1.3.6.1.4.1.674.10892.1.1100.90.1.28Description Defines if iSCSI is enab
Access Read-onlyTable 849. Managed System Services Device StatusNamemanagedSystemServicesDeviceStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.100.1.3Des
Access Not accessibleTable 854. SD Card Unit Table EntryNamesdCardUnitTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.110.1Description Defines the SD
Access Read-onlyTable 859. SD Card Unit Redundancy StatusNamesdCardUnitRedundancyStatusObject ID 1.3.6.1.4.1.674.10892.1.1100.110.1.5Description Defin
Table 864. SD Card Device Table EntryNamesdCardDeviceTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1Description Defines the SD Card Device Tabl
Table 869. SD Card Device Config CapabilitiesNamesdCardDeviceConfigCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1100.112.1.5Description Defines the c
Description Defines the storage size in MB (megabytes) of the SD card for the SD Card device.Syntax DellUnsigned32BitRangeAccess Read-onlyTable 875. S
deviceTypeIsATrackBall(4)Device type is a track ball.deviceTypeIsATrackPoint(5)Device type is a track point.deviceTypeIsAGlidePoint(6)Device type is a
Data Type:IntegerPossible Data Values Meaning of Data ValuedeviceTypeIsOther(1)The processor device type is not one of the following values:deviceType
processorUpgradeIsBySlotM(12)Upgrade is by Slot M.processorUpgradeIsByScoket423(13)Upgrade is by Socket 423.processorUpgradeIsBySocketA(14)Upgrade is
deviceFamilyIs80286(4)The processor family is 80286.deviceFamilyIs80386(5)The processor family is 80386.deviceFamilyIs80486(6)The processor family is
deviceFamilyIsK6(26)The processor family is K6.deviceFamilyIsK6-2(27)The processor family is K6-2.deviceFamilyIsK6-3(28)The processor family is K6-3.d
deviceFamilyIsAlpha21164(51) The processor family is Alpha 21164.deviceFamilyIsAlpha21164PC(52)The processor family is Alpha 21164PC.deviceFamilyIsAlp
deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II.deviceFamilyIsmicroSPARCIIep (83)The processor family is microSPARC IIep.deviceFa
2Server Administrator GroupThe Server Administrator group comprises of the following sections:• Instrumentation MIB Version Group• Systems Management
deviceFamilyIsAMDTurion64Mobile(134) The processor family is AMD Turion 64 Mobile Technology.deviceFamilyIsDualCoreAMDOpter on(135)The processor famil
deviceFamilyIsQuadCoreIntelXeon3200(161)The processor family is Quad-Core Intel Xeon processor 3200 Series.deviceFamilyIsDualCoreIntelXeon3000(162)The
deviceFamilyIsM2(177)The processor family is M2.deviceFamilyIsIntelPentium4HT (179)The processor family is Intel Pentium 4 HT processor.deviceFamilyIs
deviceFamilyIsIntelCorei7(198)The processor family is Intel Core i7 processor.deviceFamilyIsDualCoreIntelCel eron(199)The processor family is Dual-Cor
deviceFamilyIsDualCoreIntelXeo n7xxx(221)The processor family is Dual-Core Intel Xeon processor 7xxx Series.deviceFamilyIsQuadCoreIntelXeo n7xxx(222)T
deviceFamilyIsAMDOpteron4200 (61)The processor family family is AMD Opteron 4200 Series Processor.Table 884. Cache Device TypeVariable Name:DellCacheD
deviceWritePolicyIsWriteThrough(4)Device write policy is write through.deviceWritePolicyIsVariesByAddress(5)Device write policy varies by address.devi
deviceAssociativityIsOther(1)Device associativity is not one of the following:deviceAssociativityIsUnknown(2)Device associativity is unknown.deviceAss
deviceLocationIsInternal(3)Device location is internal.deviceLocationIsExternal(4)Device location is external.Table 891. Cache Device Static Random-Ac
deviceFormFactorIsAProprietaryCard(8)Device form factor is a proprietary card.deviceFormFactorIsDIMM(9) Device form factor is DIMM.deviceFormFactorIsT
Description Defines the major version number of the version of this MIB supported by the systems management software. For example, if the MIB version
deviceTypeIsEPROM(12)Device type is EPROM.deviceTypeIsCDRAM(13)Device type is CDRAM.deviceTypeIs3DRAM(14)Device type is 3DRAM.deviceTypeIsSDRAM(15)Dev
deviceTypeDetailIsCMOS(256) The detailed device type is CMOS.deviceTypeDetailIsEDO(512) The detailed device type is EDO.deviceTypeDetailIsWindowDRAM (
(0)Memory device has no faults.eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable Memory Event warning rate.eccSingleBitC
noTeam(1)Device is not part of any team.teamingEnabled(2)Teaming is enabled.adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.loadBala
Table 901. Network Device iSCSI Capability FlagsVariable Name:DellNetworkDeviceiSCSICapabilityFlagsData Type:IntegerNOTE: These values are bit fields,
none(0)SD card device has none of the following capabilities.sdCapable(1)SD media can be enabled.vFlashCapable(2)Virtual Flash (vFlash) can be enabled
offline(8)Device is offline.failed(16)Device is failed.active(32)Device is active.bootable(64)Device is bootable.writeProtect(128)Device is write-prot
Syntax DellObjectRangeAccess Read-onlyTable 911. System Slot IndexName systemSlotIndexObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.2Description Def
Access Read-onlyTable 916. System Slot TypeName systemSlotTypeObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.7Description Defines the type of the syst
Access Read-onlyTable 921. System Slot Hot-Plug Bus WidthName systemSlotHotPlugBusWidthObject ID 1.3.6.1.4.1.674.10892.1.1200.10.1.12Description De
To manage a system locally using Server Administrator, type the following in the address field of your browser: https://localhost:<1311 or user-spe
systemSlotHotPlugCanSignal Attention(8) The system slot attention state (and corresponding LED) can be set.systemSlotHotPlugCanSignal PowerFault(16) P
systemSlotHotPlugIsAtAttention(8) The system slot attention state (and corresponding LED) is on.systemSlotHotPlugHasPowerFaulted (16) Power on fault (
systemSlotIsISA(3) The system slot is Industry Standard Architecture (ISA).systemSlotIsMCA(4) The system slot is Micro Channel Architecture (MCA).syst
systemSlotIsPCIExpressGen2(171) The system slot type is PCI Express Gen 2.systemSlotIsPCIExpressGen2X1(172) The system slot type is PCI Express Gen 2
Table 930. Hot-Plug Bus WidthVariable Name: DellSystemSlotHotPlugBusWidth Data Type: IntegerPossible Data Values Meaning of Data Value busWidthIsOthe
Physical Memory Array TableThe physical memory array is the entire physical memory of a system. The example that follows shows variable values for a s
Syntax DellObjectRangeAccess Read-onlyTable 934. Physical Memory Array IndexName physicalMemoryArrayIndexObject ID 1.3.6.1.4.1.674.10892.1.1300.10.
Syntax DellPhysicalMemoryArrayUse (See Physical Memory Array ECC Type Definitions)Access Read-onlyTable 939. Physical Memory Array Error Checking an
Table 943. Physical Memory Array In Use Number SocketsName physicalMemoryArrayInUseNumberSocketsObject ID 1.3.6.1.4.1.674.10892.1.1300.10.1.11Descrip
Syntax DellObjectRangeAccess Read-onlyTable 948. Physical Memory Array Extended Maximum SizeNOTE: This attribute replaces the physicalMemoryArrayMax
Table 19. Systems Management Software Supported ProtocolName systemManagementSoftwareSupportedProtocolObject ID 1.3.6.1.4.1.674.10892.1.100.5Descript
Syntax DellObjectRangeAccess Read-onlyTable 952. Physical Memory Array Mapped IndexName physicalMemoryArrayMappedIndexObject ID 1.3.6.1.4.1.674.108
Syntax DellObjectRangeAccess Read-onlyTable 957. Physical Memory Array Mapped Starting AddressName physicalMemoryArrayMappedStartingAddressObject ID
Access Not accessibleTable 961. Physical Memory Configuration Table EntryName physicalMemoryConfigTableEntry Object ID 1.3.6.1.4.1.674.10892.1.1300.
Table 965. Physical Memory Configuration State SettingsName physicalMemoryConfigStateSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.4Descriptio
Table 970. Physical Memory Configuration MOM SettingsName physicalMemoryConfigMOMSettings Object ID 1.3.6.1.4.1.674.10892.1.1300.30.1.9Description D
Description Defines the index (one-based) of the physical memory logging.Syntax DellObjectRangeAccess Read-onlyTable 975. Physical Memory Logging Capa
Description Defines the Redundant Memory Unit Table entry.Syntax RedundantMemoryUnitTableEntryAccess Not accessibleIndex redundantMemoryUnitChassis
Table 984. Redundant Memory Unit Redundancy StatusName redundantMemoryUnitRedundancyStatusObject ID 1.3.6.1.4.1.674.10892.1.1300.50.1.5Description D
Syntax PhysicalMemoryCardTableEntryAccess Not accessibleIndex physicalMemoryCardChassisIndex,physicalMemoryCardIndexTable 989. Physical Memory Card
Table 993. Physical Memory Card StatusName physicalMemoryCardStatusObject ID 1.3.6.1.4.1.674.10892.1.1300.60.1.5Description Defines the status of th
Table 24. Systems Management Software Global Version NameName systemManagementSoftwareGlobalVersionNameObject ID 1.3.6.1.4.1.674.10892.1.100.10Descri
Syntax DellObjectRangeAccess Read-onlyMemory Group Variable ValuesThis section includes definitions for server administrator-specific variable value
Possible Data Values Meaning of Data ValuememoryArrayECCTypeIsOther(1)There is not one of the following:memoryArrayECCTypeIsUnknown(2)The memory arra
If set to 0 (zero)There are no redundant memory capabilities.unknownCapabilities(1)Redundant capabilities are unknown.The redundant capabilities are:s
If set to 0 (zero)There are no logging settings enabled. unknownCapabilities(1)Logging capabilities are unknown.The logging settings are:enabled(2)Log
Syntax BiosSetUpControlTableEntryAccess Not accessibleIndex biosSetUpControlchassisIndexTable 1008. BIOS Setup Control Chassis IndexName biosSetUpCont
Syntax DellStringAccess Read-onlyTable 1013. BIOS Setup Control Numeric Lock Control CapabilitiesNamebSUCnumLockControlCapabilitiesObject ID 1.3.6.1.4
Access Read-onlyTable 1018. BIOS Setup Control Processor Serial Number Control SettingsName bSUCprocessorSerialNumberControlSettingsObject ID 1.3.6.
Access Read-onlyTable 1023. BIOS Setup Control Speaker Control StatusName bSUCspeakerControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.10.1.16Desc
Syntax DellStatusAccess Read-onlyTable 1028. BIOS Setup Control NIF Wakeup on LAN Control NameName bSUCnIFwakeonLanControlNameObject ID 1.3.6.1.4.1.
Syntax DellStringAccess Read-onlyTable 1033. BIOS Setup Control Administrator Password Control Capabilities UniqueName bSUCadministratorPasswordCont
supportsSNMPandDMI(3) This system supports SNMP and DMI.supportsCIMOM(4) This system supports CIM.supportsSNMPandCIMOM(5) This system supports SNMP an
current administrator password immediately preceding this password change.Syntax DellStringAccess Read-onlyTable 1038. BIOS Setup Control User Passw
Description Defines the setup BIOS name of the new user password. To set a new user password, a you must have successfully set the current user passw
SCSI Control TableTable 1047. SCSI Control TableName sCSIControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.20Description Defines the Small Computer
Access Read-onlyTable 1052. SCSI Control SettingsName sCSIControlSettings Object ID 1.3.6.1.4.1.674.10892.1.1400.20.1.4Description Defines the stat
,parallelPortControlIndexTable 1057. Parallel Port Control Chassis IndexName parallelPortControlchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.30
Access Read-onlyTable 1062. Parallel Port Control NameName parallelPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.30.1.6Description Defines
,serialPortControlIndexTable 1067. Serial Port Control Chassis IndexName serialPortControlchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.1De
Table 1072. Serial Port Control NameName serialPortControlNameObject ID 1.3.6.1.4.1.674.10892.1.1400.40.1.6Description Defines the setup BIOS name o
Access Read-onlyTable 1077. USB Control CapabilitiesName usbControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1400.50.1.3Description Defines the
Access Not accessibleTable 1082. IDE Control Table EntryName ideControlTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1Description Defines the
For example, systemStatePowerSupplyStatusCombined provides the rolled up status of all power supplies for the chassis.The variables in List 2 provide
Access Read-onlyTable 1087. IDE Control StatusName ideControlStatusObject ID 1.3.6.1.4.1.674.10892.1.1400.60.1.5Description Defines the status for
Access Read-onlyTable 1092. Diskette Control IndexName disketteControlIndexObject ID 1.3.6.1.4.1.674.10892.1.1400.70.1.2Description Defines the ind
Table 1097. Network Interface Control TableName networkInterfaceControlTableObject ID 1.3.6.1.4.1.674.10892.1.1400.80Description Defines the Network
Access Read-onlyTable 1102. Network Interface Control Settings UniqueName networkInterfaceControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.140
Syntax BiosSettingTableEntryAccess Not accessibleIndex biosSettingChassisIndex,biosSettingIndexTable 1107. BIOS Setting Chassis IndexName biosSettin
Syntax DellBIOSSettingValueTypeAccess Read-onlyTable 1112. BIOS Setting Current ValueName biosSettingCurrentValueObject ID 1.3.6.1.4.1.674.10892.1.
Table 1117. BIOS Setting Group Display NameName biosSettingGroupDisplayNameObject ID 1.3.6.1.4.1.674.10892.1.1400.90.1.11Description Defines the dis
medium(8) Speaker control volume is medium.high(16) Speaker control volume is high.Table 1121. Network Interface (NIF) Wakeup on LAN Capabilities Uniq
bootFromDisketteORHardDrive FirstCapable(6) Setup BIOS can boot from a diskette or an IDE hard drive first.bootFromDeviceListCapable(8) Setup BIOS can
passwordControlJumperDisabled(4) Setup BIOS has determined that password control has been disabled by a jumper.Table 1127. BIOS Password Control Setti
Contents1 Introduction... 9What’s New in T
• systemStateSDCardUnitStatusList• systemStateSDCardDeviceStatusListSystem State TableThe following object sets up the System State Table:Table 31. Sy
lpt1Capable(4) Setup BIOS can support parallel port 1.lpt1andEnableCapable(6) Setup BIOS has enabled parallel port 1.lpt2Capable(8) Setup BIOS can sup
Table 1133. Serial Port Control CapabilitiesVariable Name: DellSerialPortControlCapabilitiesUnique Data Type: IntegerPossible Data Values Meaning of
com4(32) Setup BIOS has selected serial port 4.com4Enabled(34) Setup BIOS has enabled serial port 4.comPortsAutoConfig(64) Setup BIOS has selected aut
unknown(1) Network interface state is unknown.enabled(2) Network interface is enabled.enabledWithoutPXE(4) Network interface is enabled without PXE.Ta
Description Defines the LRA Global Settings Table.Syntax SEQUENCE OF LRAGlobalSettingsTableEntryAccess Not accessibleTable 1141. LRA Global Setting
Table 1145. LRA Global Settings Capabilities UniqueName lRAGlobalSettingsCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.1500.10.1.4Description
Table 1149. LRA Action Table EntryName lRAActionTableTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1500.20.1Description Defines the LRA Action Table e
• 1554 — log full action definition• 1603 — processor warning action definition• 1604 — processor failure action definition• 1703 — battery warning ac
rebootCapable(16) The LRA can reboot the system.powerCycleCapable(32) The LRA is capable of a system power cycle.powerOFFCapable(64) The LRA can shut
powerOFF(64) LRA is set to issue a system power off.executeApplication(256) LRA is set to start a user mode application.allLRASettingsUnique(383) LRA
Table 35. System State Chassis StateName systemStateChassisStateObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.3Description Defines the system state of
Access Not accessibleIndexcoochassisIndexTable 1159. COO Chassis IndexNamecoochassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1Description Defi
Access Read-onlyTable 1164. COO Acquisition Purchase OrderNamecooAquisitionPurchaseOrderObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.6Description Defin
Access Read-onlyTable 1169. COO Cost Center Information Vendor NameNamecooCostCenterInformationVendorNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.1
Access Read-onlyTable 1174. COO Extended Warranty Provider NameNamecooExtendedWarrantyProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.16Descri
Access Read-onlyTable 1179. COO Deployment Duration TypeNamecooDeploymentDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.21Description Defines
Access Read-onlyTable 1184. COO Outsourcing Provider Fee NameNamecooOutsourcingProviderFeeNameObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.26Descriptio
Access Read-onlyTable 1189. COO Box Central Processing Unit (CPU) Serial Number NameNamecooBoxCPUSerialNumberNameObject ID 1.3.6.1.4.1.674.10892.1.160
Access Read-onlyTable 1194. COO Depreciation Duration TypeNamecooDepreciationDurationTypeObject ID 1.3.6.1.4.1.674.10892.1.1600.10.1.36Description Def
Description Defines the COO Service Contract Table.Syntax SEQUENCE OF CooServiceContractTableEntryAccess Not accessibleTable 1199. COO Service Contrac
Table 1203. COO Service Contract Was RenewedNamecooServiceContractWasRenewedObject ID 1.3.6.1.4.1.674.10892.1.1600.20.1.4Description Specifies whether
Description Defines the status of all power units in this chassis. The results are returned as a binary octet string. Each byte of the octet string r
Access Not accessibleIndexcooCostEventLogchassisIndex,cooCostEventLogIndexTable 1208. COO Cost Event Log Chassis IndexNamecooCostEventLogchassisIndexO
Description Defines the duration type of the event for this system.Syntax DellCOOHourDayDurationType (See COO Hour Day Duration Type)Access Read-onlyT
Access Read-onlyTable 1217. COO Warranty IndexNamecooWarrantyIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.2Description Defines the index of the wa
Access Read-onlyTable 1222. COO Warranty CostNamecooWarrantyCostObject ID 1.3.6.1.4.1.674.10892.1.1600.40.1.7Description Defines the cost of the warra
Table 1226. COO Lease Information IndexNamecooLeaseInformationIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.2Description Defines the index of the l
Table 1231. COO Lease Information End Date NameNamecooLeaseInformationEndDateNameObject ID 1.3.6.1.4.1.674.10892.1.1600.50.1.7Description Defines the
,cooScheduleNumberIndexTable 1236. COO Schedule Number Chassis IndexNamecooScheduleNumberchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.60.1.1Desc
Syntax DellCostofOwnershipStringAccess Read-onlyCOO Options TableTable 1241. COO Options TableName cooOptionsTableObject ID 1.3.6.1.4.1.674.10892.1.16
Table 1245. COO Options StateName cooOptionsStateObject ID 1.3.6.1.4.1.674.10892.1.1600.70.1.3Description Defines the option information state for thi
IndexcooMaintenancechassisIndex,cooMaintenanceIndexTable 1250. COO Maintenance Chassis IndexNamecooMaintenancechassisIndexObject ID 1.3.6.1.4.1.674.10
Table 43. System State Voltage State DetailsName systemStateVoltageStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.11Description Defines the
Syntax DellDateNameAccess Read-onlyTable 1255. COO Maintenance Provider NameNamecooMaintenanceProviderNameObject ID 1.3.6.1.4.1.674.10892.1.1600.80.1.
Table 1259. COO Repair Chassis IndexNamecooRepairchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.1600.90.1.1Description Defines the index (one-based) of
COO Support Information TableTable 1264. COO Support Information TableName cooSupportInformationTableObject ID 1.3.6.1.4.1.674.10892.1.1600.100Descrip
Description Defines the support information state for this system.Syntax DellStateSettingsAccess Read-onlyTable 1269. COO Support Information Is Outso
Table 1273. COO Trouble Ticket TableNamecooTroubleTicketTableObject ID 1.3.6.1.4.1.674.10892.1.1600.110Description Defines the COO Trouble Ticket Tabl
Access Read-onlyTable 1278. COO Trouble Ticket Support Information Index ReferenceNamecooTroubleTicketSupportInformationIndexReferenceObject ID 1.3.6.
unknown(1)Duration time type is unknown.hours(2)Duration time type is in hours.days(3)Duration time type is in days.Table 1282. COO Day Month Duration
Access Not accessibleTable 1285. Remote Access Table EntryNameremoteAccessTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1Description Defines the
Access Read-onlyTable 1290. Remote Access State SettingsNameremoteAccessStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.5Description Defines
Table 1295. Remote Access Local Area Network (LAN) CapabilitiesNameremoteAccessLANCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1700.10.1.14Descriptio
Table 47. System State Amperage Status CombinedName systemStateAmperageStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.15Description Define
Table 1300. Remote Access Personal Computer Memory Card International Association (PCMCIA) Info NameNameremoteAccessPCMCIAInfoNameObject ID 1.3.6.1.4.
Table 1305. Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)NameremoteAccessNICCurrentInfoFromDHCPObject ID 1.3.6
logResetCapable(2)The remote access hardware can reset its integrated logs.hardResetCapable(4)The remote access hardware can perform a hard reset.soft
extPwrSupplyMonitorIfConn ectedCapable(2)The remote access hardware can be set to monitor the external power supply, if connected.extPwrSupplyMonitorA
unknown(1)The remote access hardware LAN settings are unknown.nicEnabled(2)The remote access hardware NIC is enabled.nicDHCPEnabled(4)The remote acces
unknownCapabilities(1)The remote access hardware out-of-band SNMP capabilities are unknown.oobSNMPAgentCapable(2)The remote access hardware has an out
none(0)The admin user has no state settings.unknown(1)The admin user state settings are unknown.enabled(2)The admin user is enabled.notReady(4)The adm
other(1)The remote user admin alpha protocol type is not one of the following:unknown(2)The remote user admin alpha protocol type is unknown.alpha7E0(
enabled(2)The SNMP trap destination is enabled.notReady(4)The SNMP trap destination is in the not ready state.Table 1326. Remote SNMP Trap Control Cap
dialInDHCPCapable(32)The dial-up functionality can support using DHCP to obtain an IP address for the dial-in feature.dialInAuthAnyCapable(64)The dial
Access Read-onlyTable 51. System State Cooling Unit State DetailsName systemStateCoolingUnitstateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.1
remoteDialUpIsOther(1)The remote dial type is not one of the following:remoteDialUpIsUnknown(2)The remote dial type is unknown.remoteDialUpIsTone(3)Th
Data Type:IntegerPossible Data Values Meaning of Data Valuenone(0)The dial-out destination has no state capabilities.unknownCapabilities(1)The dial-ou
systems. Simpler management is achieved by using virtual servers, as opposed to managing each individual computer system.Cluster GroupThe Cluster Grou
Access Read-onlyTable 1339. Cluster State CapabilitiesNameclusterStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.3Description Defines the
Table 1344. Cluster NameNameclusterNameObject ID 1.3.6.1.4.1.674.10892.1.1800.10.1.8Description Defines the name of the cluster.Syntax DellStringAcces
Syntax SEQUENCE OF BmcTableEntryAccess Not accessibleTable 1347. BMC Table EntryNamebmcTableEntryObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1Descriptio
Syntax DellStateSettingsAccess Read-onlyTable 1352. BMC StatusNamebmcStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.5Description Defines the status
Table 1357. BMC TypeNamebmcTypeObject ID 1.3.6.1.4.1.674.10892.1.1900.10.1.10Description Defines the type of the BMC.Syntax DellManagementControllerTy
Baseboard Management Controller Serial InterfaceTable 1362. BMC Serial Interface TableNamebmcSerialInterfaceTableObject ID 1.3.6.1.4.1.674.10892.1.190
Syntax DellObjectRangeAccess Read-onlyTable 1367. BMC Serial Interface State CapabilitiesNamebmcSerialInterfaceStateCapabilitiesObject ID 1.3.6.1.4.1.
the status of a specific cooling device. The first byte returned represents the status of the first cooling device, the second byte returned represent
Table 1372. BMC Serial Interface Connection Mode SettingsNamebmcSerialInterfaceConnectionModeSettingsObject ID 1.3.6.1.4.1.674.10892.1.1900.20.1.9Desc
,bmcLANInterfaceBMCIndex,bmcLANInterfaceIndexTable 1377. BMC LAN Interface Chassis IndexNamebmcLANInterfaceChassisIndexObject ID 1.3.6.1.4.1.674.10892
Access Read-onlyTable 1382. BMC LAN Interface StatusNamebmcLANInterfaceStatusObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.6Description Defines the stat
Table 1387. BMC LAN Interface Default Gateway AddressNamebmcLANInterfaceDefaultGatewayAddressObject ID 1.3.6.1.4.1.674.10892.1.1900.30.1.11Description
directPPP(16)BMC serial interface supports Direct PPP mode.directTerminal(32)BMC serial interface supports Direct Terminal mode.Table 1391. BMC Serial
Table 1394. BMC LAN IP Address Source TypeVariable Name:DellBMCLANIPAddressSourceTypeData Type:IntegerPossible Data Values Meaning of Data Value-- uns
formFactorTypeIsDualWidthHalfHeight(2)Form Factor Type is DualWidthHalfHeight.formFactorTypeIsSingleWidthFullHeight(3)Form Factor Type is SingleWidthF
,fruIndexTable 1399. FRU Chassis IndexName fruChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.1Description Defines the index (one-based) of
Table 1404. FRU Manufacturer NameName fruManufacturerName Object ID 1.3.6.1.4.1.674.10892.1.2000.10.1.6Description Defines the manufacturer of the F
Description Defines the asset tag of the FRU.Syntax DisplayString (SIZE (0..64))Access Read-onlyField Replaceable Unit Group Variable ValuesThis se
Table 58. System State Memory Device State DetailsName systemStateMemoryDeviceStateDetailsObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.26Description D
370
3Storage Management GroupThe Storage Management Group is composed of the following:• Storage Management Group—information about the software product a
4: UnknownSyntax IntegerAccess Read-onlyTable 1413. Software ManufacturerName softwareManufacturerObject ID 1.3.6.1.4.1.674.10893.1.20.3Description
Table 1417. DescriptionName descriptionObject ID 1.3.6.1.4.1.674.10893.1.20.100.2Description Provides a short description of this management softwar
Syntax IntegerAccess Read-onlyTable 1422. Agent Time StampName agentTimeStampObject ID 1.3.6.1.4.1.674.10893.1.20.110.3Description Identifies the
Table 1426. Agent HostnameName agentHostnameObject ID 1.3.6.1.4.1.674.10893.1.20.110.7Description This entry is obsolete for Storage Management.Synt
Table 1431. Agent Management Software URL NameName agentManagementSoftwareURLNameObject ID 1.3.6.1.4.1.674.10893.1.20.110.12Description Identifies t
Syntax DellStatusAccess Read-onlyTable 1434. Agent Smart Thermal ShutdownName agentSmartThermalShutdownObject ID 1.3.6.1.4.1.674.10893.1.20.110.15D
• EMM Connection Table — describes the connection between each EMM on the managed system and its enclosure. Each enclosure number in the table corresp
Description Identifies the name of the controller in this subsystem as represented in Storage Management. Includes the controller type and instance.
second intrusion detection device, and so on. The bytes have the same definition type as DellStateSettings.Syntax Octet StringAccess Read-onlyTable
Access Read-onlyTable 1442. Controller SeverityName controllerSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.6Description This entry is obsol
Syntax IntegerAccess Read-onlyTable 1446. Controller Physical Device CountName controllerPhysicalDeviceCountObject ID 1.3.6.1.4.1.674.10893.1.20.13
Description Identifies the size of memory in megabytes on the controller. If this size is 0, it is less than a megabyte. This attribute is only suppo
Access Read-onlyTable 1455. Controller C0 Port 0 NameName controllerC0Port0NameObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.20Description This entr
Description This entry is obsolete. Fibre channel is not supported in Storage Management.Syntax DisplayStringAccess Read-onlyTable 1460. Controller
Table 1464. Controller C1 TargetName controllerC1TargetObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.29Description This entry is obsolete. Fibre chan
Syntax DisplayStringAccess Read-onlyTable 1469. Controller C0 Port 1 World Wide NameName controllerC0Port1WWNObject ID 1.3.6.1.4.1.674.10893.1.20.1
Syntax DellStatusAccess Read-onlyTable 1473. Controller Component StatusName controllerComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.
Description Indicates currently installed driver version of the controllerSyntax DisplayStringAccess Read-onlyTable 1477. Controller PCI SlotName c
Access Read-onlyTable 1481. Controller SCSI Initiator IDName controllerSCSIInitiatorIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.46Description Th
Syntax DellStatusRedundancyAccess Read-onlyTable 66. System State AC Power Switch Status DetailsName systemStateACPowerSwitchStatusDetailsObject ID
Access Read-onlyTable 1486. Controller Check Consistency RateName controllerCheckConsistencyRateObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.51Descr
Table 1490. Controller Storport Driver VersionName controllerStorportDriverVersionObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.55Description Provide
Access Read-onlyTable 1494. Controller Spin Down Unconfigured DrivesName controllerSpinDownUnconfiguredDrivesObject ID 1.3.6.1.4.1.674.10893.1.20.13
Table 1498. Controller CacheCadeName controllerCacheCadeObject ID 1.3.6.1.4.1.674.10893.1.20.130.1.1.64Description Indicates if the controller is Ca
Description Indicates configured drives spin up time interval in hours. This value is added with configured drives start time to arrive at time windo
Table 1506. Channel EntryName channelEntryObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1Description Defines the channel table entry.Syntax ChannelEntr
Table 1510. Channel SeverityName channelSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.4Description This entry is obsolete for Storage Managem
Syntax DellStatusAccess Read-onlyTable 1514. Channel Component StatusName channelComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.2.1.8Descr
3: Fibre Channel4: Serial Storage Architecture (SSA)6: Universal Serial Bus (USB)7: SATA8: SAS9: PCIeSyntax IntegerAccess Read-onlyEnclosure TableTh
Description Identifies the enclosure's name as represented in Storage Management.Syntax DisplayStringAccess Read-onlyTable 1522. Enclosure Ven
System Resource Group... 87System Re
Access Read-onlyTable 70. System State Redundant Memory Unit State DetailsName systemStateRedundantMemoryUnitStateDetailsObject ID 1.3.6.1.4.1.674.1
Syntax DisplayStringAccess Read-onlyTable 1526. Enclosure Processor VersionName enclosureProcessorVersionObject ID 1.3.6.1.4.1.674.10893.1.20.130.3
Access Read-onlyTable 1531. Enclosure Product IDName enclosureProductIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.12Description Identifies the en
2: Dell PowerVault 200S (PowerVault 201S)3: Dell PowerVault 210S (PowerVault 211S)4: Dell PowerVault 220S (PowerVault 221S)5: Dell PowerVault 660F6: D
Table 1539. Enclosure AlarmName enclosureAlarmObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.20Description Identifies the current status of the enclos
Access Read-onlyTable 1543. Enclosure Component StatusName enclosureComponentStatusObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.24Description The s
Table 1547. Enclosure Part NumberName enclosurePartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.3.1.28Description The part number of the enclosure
NOTE: A value of 9999 indicates that the feature is not available.Syntax IntegerAccess Read-onlyTable 1552. Enclosure Empty Slot CountName enclosure
Access Read-onlyTable 1556. Array Disk NameName arrayDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.2Description Identifies the name of the a
34: Predictive Failure35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers.39: Foreign40: Clear41: Unsupporte
Syntax DisplayStringAccess Read-onlyTable 1563. Array Disk Enclosure IDName arrayDiskEnclosureID Object ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.9Desc
Table 74. System State Power Unit Status CombinedName systemStatePowerUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.42Description Def
Description The size in megabytes of the largest contiguous free space on the array disk. If this size is 0, it is less than a megabyte.Syntax Integ
Table 1572. Array Disk Used Space in BytesName arrayDiskUsedSpaceInBytesObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.18Description Identifies the si
Syntax IntegerAccess Read-onlyTable 1576. Array Disk Spare StateName arrayDiskSpareStateObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.22Description
4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1579. Array Disk Device NameName arrayDiskDeviceNameObject ID 1.
Description Indicates the speed at which the drive is actually running in MPS (megabytes per second).Syntax IntegerAccess Read-onlyTable 1584. Arra
Table 1588. Array Disk Manufacture YearName arrayDiskManufactureYearObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.34Description Indicates the four di
Syntax Octet StringAccess Read-onlyTable 1593. Array Disk Alta Revision IdName arrayDiskAltaRevisionIdObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.
Description Indicates drive write cache capability for PCIe SSD devices. Value: 1 - Enabled, 0 - Disabled, 99 - Undetermined/NotApplicableSyntax Int
Syntax INTEGERAccess Read-onlyTable 1602. Array Disk Read OnlyName arrayDiskReadOnlyObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.48Description Pro
Access Read-onlyTable 1606. Array Disk Max Link WidthName arrayDiskMaxLinkWidthObject ID 1.3.6.1.4.1.674.10893.1.20.130.4.1.52Description Provides
Table 78. System State AC Power Switch Status CombinedName systemStateACPowerSwitchStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.46Descrip
Description Defines the array disk enclosure connection table entry.Syntax Syntax ArrayDiskEnclosureConnectionEntryAccess Not accessibleIndexIndex a
Table 1614. Array Disk Enclosure Connection Enclosure NumberName arrayDiskEnclosureConnectionEnclosureNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.
NOTE: Only array disks that are NOT part of an enclosure are listed in this table. Backplanes are considered enclosures by Storage Management.The foll
Fan TableThis table describes available properties for each fan on the managed system.The following object sets up the Fan Table.Table 1626. Fan Table
Description Identifies the fan's (re)seller's name.Syntax DisplayStringAccess Read-onlyTable 1631. Fan StateName fanStateObject ID 1.3.6.
Description This entry is obsolete. This setting is not supported by fans managed under Storage Management.Syntax DisplayStringAccess Read-onlyTabl
Table 1639. Fan1 Part NumberName fan1PartNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.7.1.12Description Identifies the part number of the fan in the
4: Non-critical5: Critical6: Non-recoverableSyntax DellStatusAccess Read-onlyTable 1643. Fan Nexus IDNamefanNexusIDObject ID 1.3.6.1.4.1.674.10893.1
Access Not accessibleIndexfanConnectionNumberTable 1647. Fan Connection NumberNamefanConnectionNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.8.1.1Des
Description Identifies the instance number of the enclosure in the enclosureTable to which this fan belongs.Syntax IntegerAccess Read-onlyPower Supp
Table 82. System State Processor Device Status CombinedName systemStateProcessorDeviceStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.50Desc
Description Defines the capabilities of the power supply.Syntax DellPowerSupplyStateCapabilitiesUnique (Power Supply State Capabilities Unique)Acces
Syntax DellStringAccess Read-onlyTable 1662. Power Supply Input VoltageName powerSupplyInputVoltageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.9Desc
Access Read-onlyTable 1667. Power Supply Rated Input WattageName powerSupplyRatedInputWattageObject ID 1.3.6.1.4.1.674.10892.1.600.12.1.14Descriptio
Table 1671. Power Supply Connection Power Supply NameName powerSupplyConnectionPowerSupplyNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.10.1.2Descript
NOTE: Available above 1.04 firmware version.Syntax DisplayStringAccess Read-onlyTemperature Probe TableTable 1676. Temperature Probe TableName tempe
Table 1680. Temperature Probe State CapabilitiesName temperatureProbeStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.3Description Define
Access Read-onlyTable 1685. Temperature Probe Location NameName temperatureProbeLocationNameObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.8Description
Table 1690. Temperature Probe Lower Critical ThresholdName temperatureProbeLowerCriticalThresholdObject ID 1.3.6.1.4.1.674.10892.1.700.20.1.13Descrip
Table 1694. Temperature Probe Connection TableName temperatureConnectionTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.12Description Defines the temp
Syntax IntegerAccess Read-onlyTable 1699. Temperature Probe Connection Enclosure NameName temperatureConnectionEnclosureNameObject ID 1.3.6.1.4.1.6
Table 86. System State SD Card Unit Status CombinedName systemStateSDCardUnitStatusCombinedObject ID 1.3.6.1.4.1.674.10892.1.200.10.1.54Description
Index enclosureManagementModuleNumberTable 1703. Enclosure Management Module NumberName enclosureManagementModuleNumberObject ID 1.3.6.1.4.1.674.1089
Access Read-onlyTable 1707. Enclosure Management Module SeverityName enclosureManagementModuleSeverityObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.
Table 1711. Enclosure Management Module Maximum SpeedName enclosureManagementModuleMaxSpeedObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.9Description
Table 1714. Enclosure Management Module Nexus IDName enclosureManagementModuleNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.130.13.1.12Description Dur
Table 1718. Enclosure Management Module Connection NumberName enclosureManagementModuleConnectionNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.14.1.
Description Identifies the instance number of the enclosure in the enclosureTable to which this enclosure memory module belongs.Syntax IntegerAccess
Description Defines the state capabilities of the battery.Syntax DellStateCapabilitiesAccess Read-onlyTable 1728. Battery State SettingsName batter
Table 1732. Battery Connection TableName batteryConnectionTableObject ID 1.3.6.1.4.1.674.10893.1.20.130.16Description Defines the battery connection
Access Read-onlyTable 1737. Battery Connection Controller NameName batteryConnectionControllerNameObject ID 1.3.6.1.4.1.674.10893.1.20.130.16.1.4Des
Access Not accessibleTable 1741. Tape Drive NumberNametapeDriveNumberObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.1Description Instance number of th
chassis. Information is also available about the current date and time displayed on the chassis, intrusion warnings, watchdog timer, systems managemen
Access Read-onlyTable 1746. Tape Drive Bus TypeName tapeDriveBusTypeObject ID 1.3.6.1.4.1.674.10893.1.20.130.17.1.6Description The bus type of the t
Virtual Disk TableThis table describes available properties for each virtual disk on the managed system.The following object sets up the Virtual Disk
Table 1753. Virtual Device Disk NameName virtualDiskDeviceNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.3Description Identifies the device name u
Access Read-onlyTable 1756. Virtual Disk Length in MegabytesName virtualDiskLengthInMBObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.6Description Ide
Description Indicates whether the controller's write cache are used when writing to a virtual disk.Possible values:1: Enabled - Adaptec Write Ca
Description Indicates the virtual disk's RAID type. Possible values: 1: Concatenated 2: RAID-0 3: RAID-1 7: RAID-5 8: RAID-6 10: RAID-10 12: RAI
Table 1768. Virtual Disk LUN IDName virtualDiskLunIDObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.18Description This entry is obsolete. This property
Table 1771. Virtual Disk Nexus IDName virtualDiskNexusIDObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.21Description Durable unique ID for this virtua
Table 1775. Virtual Disk is CacheCadeName virtualDiskIsCacheCadeObject ID 1.3.6.1.4.1.674.10893.1.20.140.1.1.25Description Indicates if this virtual
Description A table of managed virtual disk partitions. The number of entries is related to number of partitions discovered in the system. The maximum
Table 93. Chassis State CapabilitiesName chassisStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.2Description Defines the capabilities of
Access Read-onlyTable 1784. Virtual Disk Partition SizeNamevirtualDiskPartitionSizeObject ID 1.3.6.1.4.1.674.10893.1.20.140.2.1.4Description Size of
Description An entry in the Fluid Cache table. A row in this table cannot be created or deleted by SNMP operations on columns of the table.Syntax Flu
Description Indicates the Entitlement Identifier for the license of the fluid cache subsystem.Syntax OCTET STRINGAccess Read-onlyTable 1794. Fluid C
Access Read-onlyTable 1799. Fluid Cache License Product IDNamefluidCacheLicenseProductIdObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.11Description In
Table 1804. Fluid Cache NexusNamefluidCacheNexusObject ID 1.3.6.1.4.1.674.10893.1.20.140.4.1.16Description Indicates the unique ID of the fluid cache
Valid values are 2 - Active, otherwise InactiveSyntax INTEGERAccess Read-onlyTable 1810. Fluid Cache Disk Backend Device TypeNamefluidCacheDiskBacke
Table 1814. Fluid Cache Disk Configured ModeNamefluidCacheDiskConfiguredModeObject ID 1.3.6.1.4.1.674.10893.1.20.140.5.1.8DescriptionConfigured Mode o
Table 1818. Fluid Cache Pool EntryName fluidCachePoolEntryObject ID 1.3.6.1.4.1.674.10893.1.20.140.6.1Syntax FluidCachePoolEntryAccess Not-Accessib
Syntax INTEGERAccess Read-onlyTable 1824. Fluid Cache Pool High Availability StateNamefluidCachePoolHighAvailabilityStateObject ID 1.3.6.1.4.1.674.1
Description Defines the array disk logical connection table.Syntax SEQUENCE OF arrayDiskLogicalConnectionEntryAccess Not accessibleTable 1828. Array
Table 98. Chassis NameName chassisNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.7Description Defines the user-assigned chassis name of the chassis.
Table 1832. Array Disk Logical Connection Virtual Disk NameName arrayDiskLogicalConnectionVirtualDiskNameObject ID 1.3.6.1.4.1.674.10893.1.20.140.3.1
Description Storage Management event message number.Syntax IntegerAccess Read-onlyTable 1837. Description EventName descriptionEventObject ID 1.3.
Description Durable, unique ID of the object causing the alert.Syntax DisplayStringAccess Read-onlyTable 1842. Current Status EventName currentStat
4Change Management GroupThe Change Management Group lets you monitor information about the Dell devices and software that are present on a particular
Device Group TableThe following object sets up the Device Group Table.Table 1847. Device TableNamedeviceTableObject ID 1.3.6.1.4.1.674.10899.1.5Descri
Table 1852. Device Vendor IDNamedeviceVendorIDObject ID 1.3.6.1.4.1.674.10899.1.5.1.4Description Defines the ID for the vendor supplying the device.Sy
Table 1856. Application TableNameapplicationTableObject ID 1.3.6.1.4.1.674.10899.1.6Description Defines a table of application information for the sys
Description Identifies the version of the application.Syntax DisplayStringAccess Read-onlyTable 1862. Application Display StringNameaplicationDisplayS
478
5Chassis Management Controller GroupDell Remote Access Controller Out-of-Band GroupThe Dell Remote Access Controller Out-of-Band MIB contains informat
Description Defines the asset tag name for this chassis.Syntax DellUnsigned8BitRangeAccess Read-onlyTable 104. Chassis ID ExtensionName chassisIDEx
Access Read-onlyTable 1868. DRsProductVersionNamedrsProductVersionObject ID 1.3.6.1.4.1.674.10892.2.1.1.5Description Defines the product version of a
Table 1873. DRsProductChassisNameNamedrsProductChassisNameObject ID 1.3.6.1.4.1.674.10892.2.1.1.10Description Defines the name of the chassis.Syntax D
Description Defines the data center locator of the chassis.Syntax DellStringAccess Read-onlyTable 1879. DRsProductChassisAisleNamedrsProductChassisAis
Table 1884. DRsProductChassisSystemIDNamedrsProductChassisSystemIDObject ID 1.3.6.1.4.1.674.10892.2.1.1.21Description Defines the system ID of the cha
Table 1889. DRsGlobalCurrStatusNamedrsGlobalCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.1Description Defines the overall chassis status being moni
Table 1894. DRsFanCurrStatusNamedrsFanCurrStatusObject ID 1.3.6.1.4.1.674.10892.2.3.1.6Description Defines the fan subsystem health status being monit
Table 1899. DRsCMAmbientTemperatureNamedrsCMCAmbientTemperatureObject ID 1.3.6.1.4.1.674.10892.2.3.1.11Description Defines the ambient temperature rea
Table 1904. DRsRedPrevStatusNamedrsRedPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.4Description Defines the previous redundancy status recorded by
Table 1909. DRsCMCPrevStatusNamedrsCMCPrevStatusObject ID 1.3.6.1.4.1.674.10892.2.3.2.9Description Defines the CMC health status being monitored by th
Description Defines the timestamp of the most recent power health status change.Syntax TimeTicksAccess Read-onlyTable 1915. DRsFanChangeTimeNamedrsFan
Table 109. Chassis System Location NameName chassisSystemLocationNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.18Description Defines the user-assig
Description Defines the CMC power table.Syntax SEQUENCE OF DrsCMCPowerTableEntryAccess Not-accessibleTable 1920. DRsCMC Power Table EntryNamedrsCMCPow
Description Defines the power (in watts) required by the chassis infrastructure, along with the maximum power requirements for all systems currently t
Description Defines the timestamp of the most recent chassis power accumulator reset.Syntax DellTimestampAccess Read-onlyTable 1930. DRsWattsPeakUsage
Syntax DellTimestampAccess Read-onlyTable 1935. DRsWattsReadingNamedrsWattsReadingObject ID 1.3.6.1.4.1.674.10892.2.4.1.1.13Description Defines the in
Access Read-onlyTable 1940. DRsPSUMonitoringCapableNamedrsPSUMonitoringCapableObject ID 1.3.6.1.4.1.674.10892.2.4.2.1.4Description Defines the monitor
Syntax SEQUENCE OF DrsCMCServerTableEntryAccess Not-AccessibleTable 1945. DRsCMCServerTableEntryNamedrsCMCServerTableEntryObject ID 1.3.6.1.4.1.674.10
Table 1949. DRsServerSlotNameNamedrsServerSlotNameObject ID 1.3.6.1.4.1.674.10892.2.5.1.1.4Description Defines the slot name of the CMC server.Syntax
Table 1954. DrsCASSChangeTimeNamedrsCASSChangeTimeObject ID 1.3.6.1.4.1.674.10892.2.20.10.4Description Defines the time stamp of the most recent chang
Syntax DellStringAccess Read-onlyTable 1959. DrsCA2AlertStatusNamedrsCA2AlertStatusObject ID 1.3.6.1.4.1.674.10892.2.21.10.4Description Defines the st
Syntax Octet StringAccess Read-onlyTable 1964. DRsAlertCurrentStatusNamedrsAlertCurrentStatusObject ID 1.3.6.1.4.1.674.10892.2.5000.10.4Description Cu
Field Replaceable Unit Group... 366Field Replac
Table 114. Chassis Fan Control Settings UniqueName chassisFanControlSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.23Description Defines t
500
6SNMP TrapsSNMP is frequently used to monitor systems for fault conditions such as temperature violations, hard drive failures, and so on. Management
Syntax DisplayStringTable 1968. Table Index OIDVariable Name alertTableIndexOIDObject ID 1.3.6.1.4.1.674.10892.1.5000.10.2Description Specifies the
Table 1973. Message IDVariable Name alertMsgIDObject ID 1.3.6.1.4.1.674.10892.4.5000.10.7Description Specifies the enhanced message ID for the objec
Description Line Item ExplanationMemory device: DIMM_1A Serial number: 11111111Memory device: DIMM_1B Serial number: 22222222<Additional power supp
Description Line Item ExplanationMemory device bank location: <Bank name in chassis>Specifies the name of the memory bank in the system that gen
Understanding Trap SeverityTraps often contain information about values recorded by probes or sensors. Probes and sensors monitor critical components
TrapID Name Description Severity Category Cause Supported by RAC Platformexceeded a threshold1015 alertDrscSELWarning The RAC has detected a new event
drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage. The trap variables are defined in the Dell Remote Access Controller Out-of-Band Group section.T
Table 1981. Battery TrapsTrapID Description Category SubCategory Severityalert2BatteryNormal2227 Battery state has returned to normal; or battery pres
Table 119. Chassis Identify Flash Control CapabilitiesName chassisIdentifyFlashControlCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.28Descri
Table 1985. Hardware Configuration TrapsTrapID Description Category SubCategory Severityalert2HardwareConfigurationInformation2331 Hardware configurat
TrapID Description Category SubCategory Severityalert2PowerSupplyFailure2185 Power supply has detected a failure.Error Events Power Supply CriticalTab
TrapID Description Category SubCategory Severity2377 System Event Log failure or critical event.Error Events System Event LogCriticalTable 1993. Softw
Table 1996. Storage Battery TrapsTrapID Description Category Subcategory Severityalert2StorageBatteryInformation4275 Storage battery information. Erro
TrapID Description Category Subcategory Severityalert2StorageFanFailure4201 Storage fan failure. Error Events Fan CriticalTable 2000. Storage Physical
TrapID Description Category Subcategory Severitystatus change associated with this trap.alert2StorageManagementFailure4177 Storage Management has dete
Table 2005. Audit CMC TrapsTrapID Description Category SubCategory Severityalert2CMCAuditInformation8691 Chassis Management Controller audit informati
Table 2008. Configuration IO Virtualization TrapsTrapID Description Category SubCategory Severityalert2IOVConfigurationInformation10747 IO virtualizat
TrapID Description Severity65801 Over-Temperature Problem (Upper Critical - going high)Critical65929 Over-Temperature Problem ClearedInformation131328
TrapID Description Severity2715393 Battery Failure Critical2715521 Battery Failure Cleared Information487169 CPU Thermal Trip (Over Temperature Shutdo
Table 124. Chassis Watchdog Control Capabilities UniqueName chassiswatchDogControlCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.33Desc
TrapID Description Severity552707 Power Supply AC Lost Critical552835 Power Supply AC Restored Information789249 Memory Redundancy has been LostCritic
7Storage Management Alert ReferenceStorage Management’s alert or event management features let you monitor the health of storage resources such as con
Table 2010. Storage Management Alert SeverityAlert Severity Component Status OK/Normal/Informational No action is required. The alert is provided for
NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems.Trap VariablesThe Storage Management SNMP traps use a se
Table 2015. Object OID EventNameobjectOIDEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.5Description MIB OID of the object causing the alert.Syntax Dis
Access Read-onlyTable 2020. Enhanced System FQDN EventNamesystemFQDNEventObject ID 1.3.6.1.4.1.674.10893.1.20.200.10Description Hostname of object cau
storage management messages, see the Dell OpenManage Server Administrator Messages Reference Guide available on the Dell Support website at dell.com/s
8iDRAC7 MIBThe Integrated Dell Remote Access Controller (iDRAC) MIB (filename iDRAC-SMIv1.mib/ iDRAC-SMIv2.mib) is the MIB supported by the Integrated
SNMP Operations Supported SNMP versionGET, GETNEXT, GETBULK SNMP v1, v2c and v3TRAP SNMP v1 and SNMP v2cNOTE: iDRAC7 does not support the SNMP SET op
Description This attribute defines the product name of a remote access card.Syntax StringTypeAccess Read-onlyTable 2024. RAC NameNameracShortNameObjec
Table 129. Chassis Power Button Control Capabilities UniqueName chassisPowerButtonControlCapabilitiesUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.10.1
Access Read-onlyTable 2029. RAC TypeNameracTypeObject ID 1.3.6.1.4.1.674.10892.5.1.1.7.0Description This attribute defines the type of a remote access
Table 2033. System Service TagNamesystemServiceTagObject ID 1.3.6.1.4.1.674.10892.5.1.3.2.0Description This attribute defines the service tag of the s
Description This attribute defines the form factor of the system.Syntax SystemFormFactorEnumAccess Read-onlyTable 2039. System Data Center NameNamesys
Table 2044. System System IDNamesystemSystemIDObject ID 1.3.6.1.4.1.674.10892.5.1.3.13.0Description This attribute defines the system ID of the system
Status GroupThe Status Group objects provide status information about the system and storage.Table 2049. Global System StatusNameglobalSystemStatusObj
Storage Details GroupThe Storage Details Group contains tables that provide detailed information about the external storage subsystem of the system in
Access Read-onlyTable 2054. Alert MessageVariable NamealertMessageObject ID 1.3.6.1.4.1.674.10892.5.3.1.2.0Description Message describing the alert.Sy
Table 2060. Alert Message ArgumentsVariable NamealertMessageArgumentsObject ID 1.3.6.1.4.1.674.10892.5.3.1.8.0Description Concatenated set of strings
Table 2064. Battery TrapsTrapID Description Category SubCategory SeverityBattery Normal2227 Battery state has returned to normal; or battery presence
TrapID Description Category SubCategory Severity2153 Fan failure. System Health Fan Event CriticalTable 2068. Fiber Channel TrapsTrapID Description Ca
Table 134. Chassis Reseller System IDName chassisResellerSystemIDObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.43Description Defines the chassis resell
Table 2071. NIC TrapsTrapID Description Category SubCategory SeverityNetwork Information 2091 Network information. System Health NIC Config Informatio
TrapID Description Category SubCategory SeverityPhysical Disk Warning 2298 Physical disk warning. System Health Physical Disk MinorPhysical Disk Failu
TrapID Description Category SubCategory Severity2273 The system halted because system power exceeds capacity; or the system performance degraded becau
Table 2082. Integrated Dual SD Module Redundancy TrapsTrapID Description Category SubCategory SeverityIntegrated Dual SD Module Redundancy Information
TrapID Description Category SubCategory Severity2162 Temperature sensor has detected a warning value.System Health Temperature MinorTemperature Probe
Table 2089. Voltage Probe TrapsTrapID Description Category SubCategory SeverityVoltage Probe Normal2171 Voltage sensor reading is within range.System
Table 2092. Enclosure TrapsTrapID Description Category SubCategory SeverityStorage Enclosure Information4339 Enclosure information. Storage Storage En
TrapID Description Category SubCategory Severity4233 Power supply failure. Storage Power Supply CriticalTable 2096. Storage Management Status TrapsTra
Updates Trap GroupThe Updates Trap Group contains traps that fall under the Updates event category of iDRAC7. Updates traps are traps generated in res
Configuration Trap GroupThe Configuration Trap Group contains traps that fall under the Configuration event category of the iDRAC7. Configuration trap
Table 139. Chassis System Revision NameName chassisSystemRevisionNameObject ID 1.3.6.1.4.1.674.10892.1.300.10.1.48Description Defines the revision n
9Standard Data Type DefinitionsThis appendix contains definitions for data types that are standard in most contexts across the information technology
unknownCapabilities(1)The object’s capabilities are unknown.enableCapable(2)The object can be disabled (offline, a binary 0 value) or enabled (online,
ok(3)The object’s status is OK.nonCritical(4)The object’s status is warning, noncritical.critical(5)The object’s status is critical (failure).nonRecov
the hex address 0x1029384754657687 is sent as hex: 0001 0000 0010 1001 0011 1000 0100 0111 ... Byte 1 Byte 2 Byte 3 Byte 4.Full DatesVariable Name: De
10SNMP Sample OutputThis appendix contains the sample output from the Simple Network Management Protocol (SNMP) covering the first four groups of the
1.3.6.1.4.1.674.10892.1.200.10.1.23.1 ='\02\02\02\02\02\02'1.3.6.1.4.1.674.10892.1.200.10.1.24.1 = 31.3.6.1.4.1.674.10892.1.200.10.1.25.1 =&
1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.2.1.1 = 11.3.6.1.4.1.674.10892.1.300.40.1.3.1.1 = 81.3.6.1.4.1.674.10892.1.
,uUIDchassisIndexTable 144. UUID Chassis IndexName uUIDchassisIndexObject ID 1.3.6.1.4.1.674.10892.1.300.20.1.1Description Defines the index (one-ba
Table 148. POST Log TableName postLogTableObject ID 1.3.6.1.4.1.674.10892.1.300.30Description Defines the POST Log Table.Syntax SEQUENCE OF PostLog
Access Read-onlyTable 153. POST Log State Settings UniqueName postLogStateSettingsUniqueObject ID 1.3.6.1.4.1.674.10892.1.300.30.1.4Description Def
Syntax EventLogTableEntryAccess Not accessibleIndex eventLogchassisIndex,eventLogRecordIndexTable 158. Event Log Chassis IndexName eventLogchassisIn
Inventory Collector Product Information... 4775 Chassis Managemen
Table 162. Event Log RecordName eventLogRecordObject ID 1.3.6.1.4.1.674.10892.1.300.40.1.5Description Defines the data for the specified chassis and
Description Defines the System BIOS Table.Syntax SEQUENCE OF SystemBIOSTableEntryAccess Not accessibleTable 167. System BIOS Table EntryName system
Table 171. System BIOS State SettingsName systemBIOSStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.4Description Defines the state of the sy
Table 176. System BIOS Starting AddressNamesystemBIOSStartingAddressObject ID 1.3.6.1.4.1.674.10892.1.300.50.1.9Description Defines the starting addre
Bit 3 BIOS Characteristics Not SupportedBit 4 ISA is supportedBit 5 MCA is supportedBit 6 EISA is supportedBit 7 PCI is supportedBit 8 PC Card (PCMCIA
Bit 30 Int 10h, CGA/Mono Video Services are supportedBit 31 NEC PC-98Bit 32 -47ReservedBit 48 Built-in NIC supports Magic PacketBit 49 System supports
Bit Position Meaning if SetBit 0 BIOS Boot Specification supportedBit 1 Function key-initiated Network Service boot supportedBit 2 Targeted Content Di
Table 185. Firmware IndexNamefirmwareIndexObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.2Description Defines the index (one-based) of the firmware in thi
Table 190. Firmware TypeNamefirmwareTypeObject ID 1.3.6.1.4.1.674.10892.1.300.60.1.7Description Defines the type of the firmware.Syntax DellFirmwareTy
Table 195. Intrusion TableNameintrusionTableObject ID 1.3.6.1.4.1.674.10892.1.300.70Description Defines the Intrusion Table.Syntax SEQUENCE OF Intrusi
iDRAC7 Supported SNMP Versions... 527iDRAC7 SNMP Data S
Table 200. Intrusion State SettingsNameintrusionStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.70.1.4Description Defines the settings of the intru
Table 205. Baseboard TableNamebaseBoardTableObject ID 1.3.6.1.4.1.674.10892.1.300.80Description Defines the Baseboard Table.Syntax SEQUENCE OF BaseBoa
Table 210. Baseboard State SettingsNamebaseBoardStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.4Description Defines the state settings of the
Description Defines the location name of the baseboard.Syntax DellStringAccess Read-onlyTable 216. Baseboard Manufacturer NameNamebaseBoardManufacture
Table 221. Baseboard Asset Tag NameNamebaseBoardAssetTagNameObject ID 1.3.6.1.4.1.674.10892.1.300.80.1.15Description Defines the baseboard asset tag n
lapTop(9)The chassis type is a laptop.noteBook(10)The chassis type is a notebook.handHeld(11)The chassis type is a handheld.dockingStation(12)The chas
lowSpeedCapable(2)The fan can be set to low speed.highSpeedCapable(4)The fan can be set to high speed.lowOrhighSpeedCapable(6)The fan can be set to lo
resetCapable(8)The hard-drive fault LED can be reset.Table 230. Hard-Drive Fault LED Control SettingsVariable Name : DellHDFaultLEDControlSettingsData
unknown(1)The chassis identification control’s state is unknown..enabled(2)The chassis identification control’s state is disabled (offline, a binary 0
manualPowerOffWithoutOSSh utdownCapable(128)The operator can power off without operating system shutdown.manualPowerCycleWithOSShu tdownCapable(256)Th
automaticPowerOffCapable(16)Watchdog controls can be set to automatically power off host.automaticAllExceptNotificationCap able(27)Watchdog controls c
enableCapable(2)The power button can be enabled (online) or disabled (offline).Table 239. Power Button Control SettingsVariable Name : DellPowerButton
Table 243. Baseboard TypeVariable Name : DellBaseBoardTypeData Type: IntegerPossible Data Values Meaning of Data Valueunknown(1)The baseboard type is
Table 245. Firmware TypeVariable Name : DellFirmwareTypeData Type: IntegerPossible Data Values Meaning of Data Valueother(1)The firmware type is other
Data Type: IntegerPossible Data Values Meaning of Data ValueNOTE: These values are bit fields, so combination values are possible.no features(0)This b
Table 249. Operating System Memory Chassis IndexName operatingSystemMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.1Description Define
Table 254. Operating System Memory Available Physical SizeName operatingSystemMemoryAvailablePhysicalSizeObject ID 1.3.6.1.4.1.674.10892.1.400.20.1.6
Object ID 1.3.6.1.4.1.674.10892.1.400.20.1.11Description This attribute defines the total physical memory for the operating system memory in KBytes.
Table 262. System Resource Map Chassis IndexName systemResourceMapChassisIndex Object ID 1.3.6.1.4.1.674.10892.1.500.10.1.1Description Defines the i
Description Defines the type of this system map.Syntax DellSystemResourceMapType (System Resource Map Type)Access Read-onlySystem Resource Owner Ta
1IntroductionThis reference guide provides information about the Simple Network Management Protocol (SNMP) Management Information Base (MIB) which is
Table 272. System Resource Owner State CapabilitiesName systemResourceOwnerStateCapabilitiesObject ID 1.3.6.1.4.1.674.10892.1.500.20.1.3Description
Description Defines the description name of the system resource owner.Syntax DellStringAccess Read-onlyTable 278. System Resource Owner Interface I
Table 282. System Resource I/O Port IndexName systemResourceIOPortIndexObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.2Description Defines the index (on
Table 287. System Resource I/O Port Share DispositionName systemResourceIOPortShareDispositionObject ID 1.3.6.1.4.1.674.10892.1.500.30.1.7Description
,systemResourceMemoryIndexTable 292. System Resource Memory Chassis IndexName systemResourceMemorychassisIndexObject ID 1.3.6.1.4.1.674.10892.1.500.4
Name systemResourceMemoryOwnerIndexReferenceObject ID 1.3.6.1.4.1.674.10892.1.500.40.1.6Description Defines the index to the associated system resou
System Resource Interrupt TableTable 301. System Resource Interrupt TableName systemResourceInterruptTableObject ID 1.3.6.1.4.1.674.10892.1.500.50Des
Access Read-onlyTable 306. System Resource Interrupt State SettingsName systemResourceInterruptStateSettingsObject ID 1.3.6.1.4.1.674.10892.1.500.50
Table 311. System Resource Interrupt TypeName systemResourceInterruptTypeObject ID 1.3.6.1.4.1.674.10892.1.500.50.1.9Description Defines the interru
Table 316. System Resource DMA IndexName systemResourceDMAIndexObject ID 1.3.6.1.4.1.674.10892.1.500.60.1.2Description Defines the index of system r
Kommentare zu diesen Handbüchern