Dell LATITUDE C510 Bedienungsanleitung Seite 66

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 170
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 65
Extended memory size has changed -
The amount of memory recorded in NVRAM does not match the memory installed in
the computer. Restart the computer. If the error appears again, contact Dell.
Gate A20 failure -
A memory module may be loose. Reinstall the memory modules and, if necessary,
replace them.
General failure -
The operating system is unable to carry out the command. This message is usually
followed by specific information-for example, Printer out of paper. Take the
appropriate action.
Hard-disk drive configuration error -
The computer cannot identify the drive type. Turn off the computer, remove the hard
drive, and boot the computer from a bootable floppy disk or CD. Then turn off the
computer, reinstall the hard drive, and restart the computer. Run the Hard-Disk Drive
tests as described in "Using Dell Diagnostics."
Hard-disk drive controller failure 0 -
The hard drive does not respond to commands from the computer. Turn off the
computer, remove the hard drive, and boot the computer from a bootable floppy disk
or CD. Then turn off the computer, reinstall the hard drive, and restart the computer.
If the problem persists, try another drive. Run the Hard-Disk Drive tests as described
in "Using Dell Diagnostics."
Hard-disk drive failure -
The hard drive does not respond to commands from the computer. Turn off the
computer, remove the hard drive, and boot the computer from a bootable floppy disk
or CD. Then turn off the computer, reinstall the hard drive, and restart the computer.
If the problem persists, try another drive. Run the Hard-Disk Drive tests as described
in "Using Dell Diagnostics."
Hard-disk drive read failure -
The hard drive may be defective. Turn off the computer, remove the hard drive, and
boot the computer from a bootable floppy disk or CD. Then turn off the computer,
reinstall the hard drive, and restart the computer. If the problem persists, try another
drive. Run the Hard-Disk Drive tests in "Using Dell Diagnostics."
Insert bootable media -
The operating system is trying to boot to a nonbootable floppy disk or CD. Insert a
bootable floppy disk or CD.
Invalid configuration information-please run System Setup Program -
Seitenansicht 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 169 170

Kommentare zu diesen Handbüchern

Keine Kommentare