Dell PowerVault ML6000 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Hardware Dell PowerVault ML6000 herunter. Dell PowerVault ML6000 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - SMI-S Reference Guide

www.dell.com | support.dell.comSMI-S Reference Guide Dell™ PowerVault™ ML6000

Seite 2

6 Understanding SMI-S, CIM, and MOF

Seite 3 - Contents

Dell PowerVault ML6000 SMI-S Reference Guide 7CIM Profiles and SubprofilesSMI-S defines a number of profiles that specify the managed objects that con

Seite 4 - B References 35

8 CIM Profiles and SubprofilesFigure 1 Storage Library Profile, Version 1.2

Seite 5

Dell PowerVault ML6000 SMI-S Reference Guide 9Storage Library SubprofilesThe following subprofiles are available for the storage library profile.Libra

Seite 6

10 CIM Profiles and SubprofilesElement Counting SubprofileThe Element Counting Subprofile defines methods to count the number of physical tapes, stora

Seite 7 - Managing SANs With SMI-S

Dell PowerVault ML6000 SMI-S Reference Guide 11Service Discovery and CIM IndicationsThis chapter explains how to discover the CIM server embedded with

Seite 8 - Understanding CIM

12 Service Discovery and CIM IndicationsDiscovering the CIM ServerWhen you discover the CIM server that is embedded within your library, you not only

Seite 9 - Understanding MOF

Dell PowerVault ML6000 SMI-S Reference Guide 13Using CIM IndicationsA CIM indication is a message that communicates a change in the status of an SMI-S

Seite 10

14 Service Discovery and CIM IndicationsTable 2 Supported Queries for CIM Indications Area of LibraryQuery PurposeLibrary SELECT * FROM CIM_InstCreati

Seite 11 - CIM Profiles and Subprofiles

Dell PowerVault ML6000 SMI-S Reference Guide 15SELECT * FROM CIM_InstModification WHERE SourceInstance ISA CIM_MediaAccessDevice AND PreviousInstance.

Seite 12

Information in this document is subject to change without notice.© 2005 - 2010 Dell Inc. All rights reserved.Trademarks used in this text: Dell, the D

Seite 13 - Storage Library Subprofiles

16 Service Discovery and CIM Indications

Seite 14 - Element Counting Subprofile

Dell PowerVault ML6000 SMI-S Reference Guide 17MOF FilesThe Managed Object Format (MOF) files for the PowerVault ML6000 library are reproduced below.M

Seite 15 - CIM Clients

18 MOF Files// ===================================================================// Chassis// =======================================================

Seite 16 - Discovering the CIM Server

Dell PowerVault ML6000 SMI-S Reference Guide 19{};// ===================================================================// FCPort// ==================

Seite 17 - Using CIM Indications

20 MOF Files [Description("CMPI SMIS ElementConformsToProfile provider"), provider("cmpi::cmpielementconformstoprofile") ]cl

Seite 18

Dell PowerVault ML6000 SMI-S Reference Guide 21// ObjectManager// ================================================================== [Description(&quo

Seite 19

22 MOF Files// ==================================================================// CommMechanismForManager// ========================================

Seite 20

Dell PowerVault ML6000 SMI-S Reference Guide 23{};// ==================================================================// NamespaceInManager// =======

Seite 21 - MOF Files

24 MOF Files [Description("CMPI SMIS TapeDrive provider"), provider("cmpi::cmpitapedrive") ]class SMIS_TapeDrive : CIM_TapeDr

Seite 22 - 18 MOF Files

Dell PowerVault ML6000 SMI-S Reference Guide 25};// ==================================================================// PhysicalMediaInLocation// ===

Seite 23

Dell PowerVault ML6000SMI-S Reference Guide iiiContents1 About This Guide and Your Product 1Explanation of Symbols and Notes . . . . . . . . . . . . .

Seite 24 - 20 MOF Files

26 MOF Files ]class SMIS_PackageInChassis : CIM_PackageInChassis{};*/// ==================================================================// ProtocolC

Seite 25

Dell PowerVault ML6000 SMI-S Reference Guide 27 [Description("CMPI SMIS ElementSoftwareIdentity provider"), provider("cmpi::cmpiel

Seite 26 - 22 MOF Files

28 MOF Files// RemoteServiceAccessPoint// ================================================================== [Description("CMPI SMIS RemoteServic

Seite 27

Dell PowerVault ML6000 SMI-S Reference Guide 29// ==================================================================// CommMechanismForManagerAdapter/

Seite 28 - 24 MOF Files

30 MOF Filesclass SMIS_PortImplementsEndpoint : CIM_PortImplementsEndpoint{};// ==================================================================//

Seite 29

Dell PowerVault ML6000 SMI-S Reference Guide 31 ]class SMIS_AuthorizedPrivilege : CIM_AuthorizedPrivilege{};// =======================================

Seite 30 - 26 MOF Files

32 MOF Files// ================================================================== [Description("CMPI SMIS StorageClientsettingData provider"

Seite 31

Dell PowerVault ML6000 SMI-S Reference Guide 33// ===================================================================// SPIPort// ====================

Seite 33

Dell PowerVault ML6000 SMI-S Reference Guide 35ReferencesThis Appendix lists some web resources and popular Common Information Model (CIM)-XML tools.W

Seite 34 - 30 MOF Files

iv ContentsA MOF Files 17MOF File for the PowerVault ML6000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 35

36 References

Seite 36 - 32 MOF Files

Dell PowerVault ML6000 SMI-S Reference Guide 37SMI-S Common Protocol InterfaceSpecificationThis section provides a detailed list of the SMI-S feature

Seite 37

38 SMI-S Common Protocol Interface Specification• Limited Access Port subprofile• Software subprofileThe following subprofiles are used in modeling; h

Seite 38 - 34 MOF Files

Dell PowerVault ML6000 SMI-S Reference Guide 39RequirementsGeneral Purpose SMI-S ServerOverviewThe General Purpose SMI-S Server role can provide a hos

Seite 39 - References

40 SMI-S Common Protocol Interface SpecificationFigure 3 Instance Diagram for Server ProfileTable 4 Required Properties for ObjectManagerProperty Type

Seite 40 - 36 References

Dell PowerVault ML6000 SMI-S Reference Guide 41Table 5 Required Server Level Instances of ObjectManagerTable 6 Required Properties for HostedServiceTa

Seite 41 - Specification

42 SMI-S Common Protocol Interface SpecificationTable 8 Required Properties for RegisteredProfileTable 9 Required Server Level Instances of Registered

Seite 42 - Architecture

Dell PowerVault ML6000 SMI-S Reference Guide 43Table 10 Required Properties for RegisteredSubProfileTable 11 Required Server Level Instances of Regist

Seite 43 - Requirements

44 SMI-S Common Protocol Interface SpecificationTable 12 Required Properties for SubProfileRequiresProfileProperty Instance 5 Instance 6 Instance 7 I

Seite 44

Dell PowerVault ML6000 SMI-S Reference Guide 45Table 13 Required Server Level Instances of SubProfileRequiresProfileTable 14 Required Properties for E

Seite 45

Dell PowerVault ML6000 SMI-S Reference Guide 1About This Guide and Your ProductThis reference guide provides a high-level overview of Storage Manageme

Seite 46

46 SMI-S Common Protocol Interface SpecificationTable 17 Required Server Level Instances of NamespaceTable 18 Required Properties for NamespaceInManag

Seite 47

Dell PowerVault ML6000 SMI-S Reference Guide 47Table 20 Required Properties for CIMXMLCommunicationMechanismProperty Type Description/NotesElementName

Seite 48

48 SMI-S Common Protocol Interface SpecificationTable 21 Required Server Level Instances for CIMXMLCommunicationMechanismTable 22 Required Properties

Seite 49

Dell PowerVault ML6000 SMI-S Reference Guide 49Table 24 Required Properties for ComputerSystemTable 25 Required Properties for ComputerSystemProperty

Seite 50

50 SMI-S Common Protocol Interface SpecificationStorage Library Profile ContentFigure 4 ComputerSystem-Centric Instance Diagram of StorageLibrary Prof

Seite 51

Dell PowerVault ML6000 SMI-S Reference Guide 51Table 26 Required Container Level Instances of ComputerSystemTable 27 Required Properties for ChassisPr

Seite 52

52 SMI-S Common Protocol Interface SpecificationTable 28 Required Container Level Instances of ChassisTable 29 Required Properties for LocationTable 3

Seite 53

Dell PowerVault ML6000 SMI-S Reference Guide 53Table 32 Required Server Level Instances of PhysicalElementLocationFigure 5 Instance Diagram of Compute

Seite 54

54 SMI-S Common Protocol Interface SpecificationTable 35 Required Properties for ProductTable 36 Required Container Level Instances of ProductTable 37

Seite 55

Dell PowerVault ML6000 SMI-S Reference Guide 55Table 39 Required Properties for SoftwareIdentityTable 40 Required Container Level Instances of Softwar

Seite 56

2 About This Guide and Your ProductOther Documents you Might NeedThe following documents are also available for this product. These documents can be f

Seite 57

56 SMI-S Common Protocol Interface SpecificationTable 42 Required Server Level Instances of InstalledSoftwareIdentityTable 43 Required Properties for

Seite 58

Dell PowerVault ML6000 SMI-S Reference Guide 57Table 46 Required Container Level Instances of ConfigurationCapacityNote: Total RAW capacity is compute

Seite 59

58 SMI-S Common Protocol Interface SpecificationTable 48 Required Library Level Instances of SystemDevice* For FCPort, SCSIProtocolEndpoint and SCSIPr

Seite 60

Dell PowerVault ML6000 SMI-S Reference Guide 59Table 51 Required Library Level instances of RealizesPropertyAccessor Instances (one for each partition

Seite 61

60 SMI-S Common Protocol Interface SpecificationTable 52 Required Properties for FCPortProperty Type Description/NotesSystemCreationClassName[key] Str

Seite 62

Dell PowerVault ML6000 SMI-S Reference Guide 61Table 53 Required Direct Attached Drive Front-End Ports Instances of FCPortTable 54 Required Properties

Seite 63

62 SMI-S Common Protocol Interface SpecificationTable 55 Required Library Level Instances of SASPortTable 56 Required Properties for SPIPortProperty V

Seite 64

Dell PowerVault ML6000 SMI-S Reference Guide 63Table 57 Required Library Level Instances of SPIPortTable 58 Required Properties for ChangerDevicePrope

Seite 65

64 SMI-S Common Protocol Interface SpecificationTable 59 Required Server Level Instances of ChangerDeviceTable 60 Required Properties for ProtocolCont

Seite 66

Dell PowerVault ML6000 SMI-S Reference Guide 65Table 62 Required Properties for SCSIProtocolControllerProperty Type Description/NotesComments/RemarksS

Seite 67

Dell PowerVault ML6000 SMI-S Reference Guide 3Understanding SMI-S, CIM, and MOFThe ML6000 library supports the industry standard SMI-S application pro

Seite 68

66 SMI-S Common Protocol Interface SpecificationTable 63 Required Server Level Instances of SCSIProtocolControllerTable 64 Required Properties of SCSI

Seite 69

Dell PowerVault ML6000 SMI-S Reference Guide 67Table 65 Required Library Instances of SCSIProtocolEndpointTable 66 Required Properties of PortImplemen

Seite 70

68 SMI-S Common Protocol Interface SpecificationTable 69 Required Library Instances of SAPAvailableForElementTable 70 Required Properties for ElementS

Seite 71

Dell PowerVault ML6000 SMI-S Reference Guide 69Table 72 Required Properties for TapeDriveProperty Type Description/NotesComments/RemarksSystemCreation

Seite 72

70 SMI-S Common Protocol Interface SpecificationTable 73 Required Server Level Instances of TapeDriveTable 74 Required Properties for PackageInChassis

Seite 73

Dell PowerVault ML6000 SMI-S Reference Guide 71Table 77 Required Library Level Instances of PhysicalPackageTable 78 Required Properties for PhysicalTa

Seite 74

72 SMI-S Common Protocol Interface SpecificationTable 79 Required Server Level Instances of PhysicalTapeTable 80 Required Properties for PackagedCompo

Seite 75

Dell PowerVault ML6000 SMI-S Reference Guide 73Table 83 Required Server Level Instances of StorageMediaLocation* Properties inherited from the supercl

Seite 76

74 SMI-S Common Protocol Interface SpecificationTable 88 Required Properties of LimitedAccessPortTable 89 Required Library Level Instances of LimitedA

Seite 77

Dell PowerVault ML6000 SMI-S Reference Guide 75Table 92 Creation/Deletion of a TapeDriveTable 93 Creation/Deletion of a ChangerDeviceTable 94 Creation

Seite 78

4 Understanding SMI-S, CIM, and MOFYour Library, SMI-S, and CIMA CIM server is embedded within the ML6000 library. The CIM server is SMI-S compliant a

Seite 79

76 SMI-S Common Protocol Interface SpecificationTable 97 Change in Operational Status of a TapeDriveTable 98 Change in Operational Status of a Changer

Seite 80

Dell PowerVault ML6000 SMI-S Reference Guide 77Fibre Channel Blade SupportThis support for Fibre Channel blades is provided through objects belonging

Seite 81 - Fibre Channel Blade Support

78 SMI-S Common Protocol Interface SpecificationTable 100 Fibre Channel I/O Blade Instances of Computer System Table 101 Required Properties for Compo

Seite 82

Dell PowerVault ML6000 SMI-S Reference Guide 79Table 103 Required Blade Instances of FCPortTable 104 Required Blade Instances of SCSIProtocolControlle

Seite 83

80 SMI-S Common Protocol Interface SpecificationTable 105 Required Blade Instances of SCSIProtocolEndpointTable 106 Required Blade Instances of PortIm

Seite 84

Dell PowerVault ML6000 SMI-S Reference Guide 81Table 109 Required Blade Instances of SystemDeviceTable 110 Required Blade Instances of InstalledSoftwa

Seite 85

82 SMI-S Common Protocol Interface SpecificationLUN Mapping (EVPS)The implementation of LUN Mapping is done for blade systems and is applicable for wh

Seite 86 - LUN Mapping (EVPS)

Dell PowerVault ML6000 SMI-S Reference Guide 83Table 113 Required Properties for StorageHardwareIDTable 114 Required Instances for StorageHardwareIDTa

Seite 87

84 SMI-S Common Protocol Interface SpecificationTable 117 Required Properties for AuthorizedPrivilegeTable 118 Required Instances for AuthorizedPrivil

Seite 88

Dell PowerVault ML6000 SMI-S Reference Guide 85Table 123 Required Properties for AuthorizedTargetTable 124 Required Instances for AuthorizedTargetTabl

Seite 89

Dell PowerVault ML6000 SMI-S Reference Guide 5After you have defined the NetworkDevice class, you can define a class for just switches. Since a switch

Seite 90

86 SMI-S Common Protocol Interface SpecificationTable 126 Required Instances for ProtocolControllerMaskingCapabilitiesTable 127 Required Properties of

Seite 91

Dell PowerVault ML6000 SMI-S Reference Guide 87Table 128 Required Instances for ElementCapabilitiesTable 129 Lun Mapping Instances of SCSIProtocolCont

Seite 92

88 SMI-S Common Protocol Interface Specification

Seite 93

Dell PowerVault ML6000 SMI-S Reference Guide 89IndexCCIMabout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4CIM-XML . . . . . . .

Kommentare zu diesen Handbüchern

Keine Kommentare